Table 6-64. Minimum Required Wait-States at Different Frequencies
(1)
(continued)
SYSCLKOUT (MHz)
SYSCLKOUT (ns)
PAGE WAIT-STATE
(2)
RANDOM WAIT STATE
(2) (3)
4
250
0
1
150
Electrical Specifications
Copyright © 2009–2010, Texas Instruments Incorporated