5-4. Setting Items of the Secondary Station on Monitor S-BUS (BKDS-V3293B only)
SET MONITOR FUNCTION DVS-V6464B Monitor Bus I/F V2.10 STATION NUMBER 23
MODIFICATION COMMAND
M: SET AVAILABLE MONITOR LINE INPUT=( ENABLE )OUTPUT=( ENABLE )
Ctrl-Z:RETURN
MONITOR SYSTEM SETUP MENU. BKS-R3204 V3.10 STATION NUMBER 6
Station Number ?
Ctrl-E:MENU Ctrl-Z:RETURN
Cascade
Cascade
Input Monitor
Output
Monitor
Monitor
Output
Monitor
Monitor
Cascade
Cascade
Input Monitor
128
65
64
1
1
64
65
128
E
D
DVS-V6464B
D
DVS-V6464B
DVS-V6464B
DVS-V6464B
E
E
E
E : Enable
D : Disable
5-4. Setting Items of the Secondary
Station on Monitor S-BUS
(BKDS-V3293B only)
(BKDS-V3293B only)
M: SET AVAILABLE MONITOR LINE
(DVS-V3232B/V6464B
+
+
+
+
+
BKDS-R3292B)
Menu Screen of the Secondary Station on Monitor S-BUS
(DVS-V3232B/V6464B)
(DVS-V3232B/V6464B)
Purpose
This menu is used to set the input monitor and output
monitor to valid or invalid.
monitor to valid or invalid.
Setting Procedure
1.
Select menu item [M].
2.
Select the source/destination using the cursor, and
press [Enter] to change the setting. (“ENABLE”
press [Enter] to change the setting. (“ENABLE”
→
“DISABLE”
→
“ENABLE”)
3.
Press [Ctrl]
_ [Z] to display the menu screen of the
primary station on the monitor S-BUS.
n
Be sure to set the monitor line to “DISABLE” in cascade
connection.
If set to “ENABLE”, the monitor may not be performed
properly.
Be sure to set the monitor line to “DISABLE” in cascade
connection.
If set to “ENABLE”, the monitor may not be performed
properly.
L : COPY TABLE DATA <MONITOR MENU>
Purpose
This menu is used to copy the setting contents of the
remote control unit. This is applied to BKS-R3204 and
BKS-R3205.
BKS-R3205.
Setting Procedure
1.
Select menu item [L]. This item can be selected from
both the menu and another setting screen.
both the menu and another setting screen.
2.
The message “Station Number?” will be displayed.
Enter the station number to be copied.
Enter the station number to be copied.
3.
When [Enter] is pressed, the table data will be copied
and the screen will return to the setting screen.
and the screen will return to the setting screen.
When [Ctrl]
_ [E] is pressed again, the menu screen
of the secondary station on the monitor S-BUS will be
displayed.
4.
When [Ctrl]
_ [Z] is pressed, menu screen of the
primary station on the monitor S-BUS will be dis-
played.
played.
Example of Setting Screen
Data set on the menu item [N : SET PANEL TABLE] are
copied.
copied.