Motorola PTP 500 사용자 설명서

다운로드
페이지 20
Attention 
E
lectro
M
agnetic 
D
ischarge 
(Lightning)
 
Protect Your Installation!  
 
EMD
 
(Lightning)
 damage is not covered under warranty 
 
 
The recommendations in this section and in the user manual, when followed correctly, 
give the installation the best protection from the harmful effects of 
EMD 
 
                    However 100% protection is not implied or possible 
The recommended components for protecting an installation are:
 
• 
Solid screen Ethernet cable: Superior Essex type BBDGE. 
 
• 
Surge Arrestor: Type PTP-LPU - 2 per link – Part Number 2978 
• 
Grounding Stake (if no suitable grounding point can be found). 
• 
Minimum 8 AWG Grounding Cable   
 
NB: There may be a local regulatory requirement to cross bond the CAT 5e cable to 
the mast at intervals as regular as every 10 metres (33 feet). This can be achieved 
using an Andrew grounding assembly type 223158 or similar. 
 
We recommend that the practices and procedures detailed in the Motorola manual R56 "STANDARDS AND 
GUIDELINES FOR COMMUNICATION SITES" (68P81089E50) be applied to all new site build activities.   For a 
copy on the manual please see your local Motorola representative.  The manual can be downloaded from the 
Motorola Intranet site 
http://compass.mot.com/go/190860869 
 
Protect Your Installation