Delta Electronics ASDA-B Series 사용자 설명서

다운로드
페이지 321
Chapter 5  Trial Run and Tuning Procedure|ASDA-B Series
 
5-10  
 
Revision January 2009
 
The settings of speed command: 
P1-09 is set to 3000 
Input value command 
Rotation direction 
P1-10 is set to 100 
CCW 
P1-11 is set to -3000 
CW 
STEP 3: 
1.  The users can use DI1 to enable the servo drive (Servo ON). 
2.  If DI3 (SPD0) and DI4 (SPD1) are OFF both, it indicates S1 command is selected. At this time, the 
motor speed command is 0(zero). 
3.  If only DI3 is ON (SPD0), it indicates S2 command (P1-09 is set to 3000) is selected, and the motor 
speed should be 3000rpm at this time. 
4.  If only DI4 is ON (SPD1), it indicates S3 command (P1-10 is set to 100) is selected, and the motor 
speed should be 100rpm at this time. 
5.  If DI3 (SPD0) and DI4 (SPD1) are ON both, it indicates S4 command (P1-11 is set to -3000) is 
selected, and the motor speed should be -3000rpm at this time. 
6.  Repeat the action of (3), (4), (5) freely. 
7.  When the users want to stop the speed trial run, use DI1 to disable the servo drive (Servo OFF).