Datalogic Scanning Matrix-1000 사용자 설명서

다운로드
페이지 67
Matrix-1000™ Reference Manual 
 
USER INTERFACE
VS
MATRIX 
A
Vext 
B
V
+
V
CC
 
~
~
+
-
GND 
OUT 
30 Vdc Max.
 
Figure 28 - Input NPN Command Using External Power 
 
 
USER INTERFACE
VS
MATRIX 
A
B
GND
V
+
V
CC
 
~
~
+
-
GND 
9
OUT
25 
 
Figure 29 - Input NPN Command Using Matrix-1000
 Power 
 
 
The electrical features of the input are: 
 
INPUT | 
AB 
| Min. 
| V 
AB 
| Max. 
IN
 Max
.
Open 
0 V 
2 V 
0 mA 
Closed 
4.5 V 
30 V 
10 mA 
 
An anti-disturbance filter (debounce filter) is implemented on the input, and is software 
programmable. The
 
input active state can be defined by the user as well. Refer to the Digital 
I/O folder in the VisiSet™ Help On Line for further details. 
 
 
3.3.5 Output 
 
One optocoupled general purpose output is available on the 25-pin connector. The pinout is 
the following: 
 
Pin Name  Function 
16 
OUT3+ 
Configurable digital output 3 - positive pin 
17 
OUT3- 
Configurable digital output 3 - negative pin 
 
It is typically used to signal the data collection result. It can also be used to control an 
external lighting system. 
 
 
The idle state, the activation/deactivation events and the other configuration parameters can 
be defined by the user. Refer to the Digital I/O folder in the VisiSet™ Help On Line for further 
details. 
 
 
 
28