The electrical features of the input are:
INPUT |
V
AB
| Min.
| V
AB
| Max.
I
IN
Max
.
Open
0 V
2 V
0 mA
Closed
4.5 V
30 V
10 mA
An anti-disturbance filter (debounce filter) is implemented on the input, and is software
programmable. The
input active state can be defined by the user as well. Refer to the Digital
I/O folder in the VisiSet™ Help On Line for further details.
3.3.5 Output
One optocoupled general purpose output is available on the 25-pin connector. The pinout is
the following:
Pin Name Function
16
OUT3+
Configurable digital output 3 - positive pin
17
OUT3-
Configurable digital output 3 - negative pin
It is typically used to signal the data collection result. It can also be used to control an
external lighting system.
The idle state, the activation/deactivation events and the other configuration parameters can
be defined by the user. Refer to the Digital I/O folder in the VisiSet™ Help On Line for further
details.