Nortel Networks 8683POS 사용자 설명서

다운로드
페이지 154
106
Chapter 6 Command line interface
209564-A
  
Figure 37   show ports stats pos felinecurrent command output
 describes the information fields for output of the 
show ports stats 
pos felinecurrent
 command.
Table 38   Information fields for output of the show ports stats pos felinecurrent 
command
Field Description
PORT NUM 
Port number.
ERRORED SECONDS 
COUNT (ES)
Errored Second (ES) is a second with one or more Coding 
Violations (CV) or one or more incoming defects (for 
example, SEF, LOS, AIS, LOP).
SEVERELY ERRORED 
COUNT (SES)
Severely Errored Second (SES) is a second with x or more 
CVs, or one or more incoming defects.
CODE VIOLATION COUNT 
(CV-L)
Coding Violations (CV) are Bit Interleaved Parity (BIP) 
errors that are detected in the incoming signal. CV 
counters are incremented for each BIP error detected.
UNAVAILABLE SECONDS
Number of seconds that the interface is unavailable.
Passport-8610:5/show/ports/stats/pos# felinecurrent
======================================================================
POS Far End Line Current Stats
======================================================================
PORT     ERRORED SECONDS   SEVERELY ERRORED   CODE VIOLATION UNAVAILABLE
NUM      COUNT (ES)        COUNT (SES)        COUNT (CV-L) SECONDS(UAS)
----------------------------------------------------------------------
10/5
 0                 0                  0                 0
10/6
 0                 0                  0                 0
Passport-8610:5/show/ports/stats/pos#