Configuring the SNMP subagent in the Avaya Ethernet switch (if used)
Installing and Configuring the Avaya S8500 Media Server
February 2007
31
 
Note:
Note:
For the Ethernet switch to report alarms properly, you must also configure the IP 
addresses for the Ethernet switches in the media servers.
Default IP addresses for the Ethernet switch 
The following table shows the default values for the Ethernet switch.
For how to administer the SNMP subagent in the Ethernet switch, see 
Preparing to configure the Ethernet switch 
Before you configure the Ethernet switch, you must complete the following prerequisites:
The Ethernet switch power cord is connected to the back of the switch and to the back of a 
UPS.
The communication protocol on your computer has the following port settings so that you 
can use your terminal emulation program:
- 9600 baud
- No parity
- 8 data bits
- 1 stop bit
- No flow control
Note:
Note:
Avaya Terminal Emulation and HyperTerminal are supported terminal emulation 
applications.
If a Network Management System (NMS) is to monitor the Ethernet switch, you 
coordinated the assignment of community names with the network administrator. If an 
NMS is not used, you set the community names to unique string values.
Parameter
Single control 
network (CNA)
Duplicated control 
network (CNB)
IP address for the Ethernet switch
198.152.254.240
198.152.255.240
Subnet mask for the Ethernet switch
255.255.255.0
255.255.255.0
IP address for the 
trap receiver (media server)
Customer provided
Customer provided