Fujitsu F2 MC-16 사용자 설명서

다운로드
페이지 354
98
CHAPTER 2  DEPENDENCE FUNCTIONS
[Setup Examples]
- Terminate sequencer when event 1 occurs.
>SET SEQUENCE/EVENT 1,1,J=0
- Terminate sequencer when event 2 occurs 16 times.
>SET SEQUENCE/EVENT 1,2,16,J=0
- Terminate sequencer when event 2 occurs after event 1 occurred. However, do not terminate sequencer
if event 3 occurs between event 1 and event 2.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/EVENT 2,3,J=1
- Terminate sequencer if and when event 2 occurs less than 300 
μs after event 1 occurred.
>SET SEQUENCE/EVENT 1,1,J=2
>SET SEQUENCE/EVENT 2,2,J=0
>SET SEQUENCE/TIMER 2,300,J=1
>SHOW SEQUENCE
Sequencer Enable
 level1   level2   level3   level4   level5   level6   level7   level8
1 |1|->2  | |       
| |       | |  
     | |  
     | |  
     | |  
     | |
2 | |
 |2|->end | |       | |  
     | |  
     | |  
     | |  
     | |
3 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
4 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
5 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
6 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
7 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
8 | |
 | |       | |   
    | |  
     | |  
     | |  
     | |  
     | |
T | |
 |T|->1
 | |       | |   
    | |  
     | |  
     | |  
     | |
 Latch 1 ( -> ) =
Latch 2 ( -> ) =
>SHOW SEQUENCE 2
level no. = 2
event
 pass-count
  
 trace-cnt1
  jmp-level1
2
 
1
 
 
 
enable
  end
timer
 00:00:000:300:000   enable
  1
Indicates
move to level
2 when event
1 occurs at
level 1
Indicate s terminating
sequencer when event 2
occurs at level 2.
Indicates move to level 1 if and
when 300 
μ
s passed before
event 2 occurs at level 2