Seagate ST200FX0002 사용자 설명서

다운로드
페이지 74
10
Pulsar XT.2 SAS Product Manual, Rev. B
When a region of LBA's are erased via cryptographic erase, as part of the erase, the drive shall unmap those 
LBAs.
If the host attempts to access an unmapped or trimmed LBA, the drive shall return scrambled data. For a given 
LBA, the data shall be identical from access to access, until that LBA is either updated with actual data from 
the host or that LBA is cryptographically erased. The drive shall report a value of '0' in the LBPRZ field returned 
in the READ CAPACITY (16) parameter data.
If the host attempts to access an unmapped LBA on a drive that has been formatted with Protection Informa-
tion (PI), the drive shall return scrambled PI data for that LBA. Depending on the value of the RDPROTECT 
field in the data-access command CDB, this may result in the drive returning a standard PI error to the host.
If the host reduces the addressable capacity of the drive via a MODE SELECT command, the drive shall 
unmap or trim any LBA within the inaccessible region of the device.
Additionally, an UNMAP command is not permitted on a locked band.
Table 3: 
PI and SED Drive Configuration
Drive Configuration
Standard
SED
PI Setting
Disabled
Enabled
Disabled
Enabled
PROT_EN bit
0
1
0
1
LBPME bit
1
1
1
1
LBPRZ bit
1
1
0
0
PI Check Requested
N/A
Yes
No
N/A
Yes
No
DATA Returned for
 
Thin Provisioned LBA
0x00
0x00
0x00
Random
None
Random
PI Returned for
 
Thin Provisioned LBA
None
0xFF
0xFF
None
None
Scrambled
 
PI data
PI Check Performed
N/A
No
No
N/A
Yes
No
Error reported to Host
No
No
No
No
Yes
No