Spinpoint M8U-Internal Product Manual REV 3.4 
93 
INSTALLATION 
 
 
 
6.4.4.4  Device Error Handling 
The device  may not be able to fully satisfy  the host's request.  At the point when the device  discovers  that it 
cannot fully satisfy  the request,  there  may be a Data-In  or Data-Out  transfer  in progress  on the bus, and the 
host  may  have  other  pending  requests.  The  device  may  cause  the  host  to  terminate  such  transfers  by 
STALLing  the appropriate  pipe. 
The response of a device to a CBW that is not meaningful  is not specified. 
Please  note that whether  or not a STALL  handshake  actually  appears  on the bus depends  on whether  or not 
there is a transfer in progress at the point in time when the device is ready to STALL the pipe. 
 
 
 
6.4.4.5  Host Error Handling 
If the host receives  a CSW which is not valid, then the host shall perform  a Reset Recovery.  If the host 
receives a CSW which is not meaningful,  then the host may perform a Reset Recovery. 
 
 
 
6.4.4.6  Error Classes 
In every transaction  between  the host and the device,  there are four possible  classes  of errors.  These  classes 
are not always independent  of each other and may occur at any time during the transaction. 
 
 
 
6.4.4.6.1 
CBW Not Valid 
If the  CBW  is not  valid,  the  device  shall  STALL  the  Bulk-In  pipe.  Also,  the  device  shall  either  STALL  the 
Bulk-Out  pipe, or the device  shall accept  and discard  any Bulk-Out  data.  The device  shall  maintain  this state 
until a Reset Recovery. 
 
 
 
6.4.4.6.2 
Internal Device Error 
The device  may detect  an internal  error for which it has no reliable  means  of recovery  other than a reset. The 
device shall respond to such conditions  by: 
either STALLing  any data transfer in progress and returning  a Phase Error status (bCSWStatus  = 02h). 
or STALLing  all further requests on the Bulk-In and the Bulk-Out  pipes until a Reset Recovery. 
 
 
 
6.4.4.6.3 
Host/Device Disagreements 
After  recognizing  that  a CBW  is valid  and  meaningful,  and  in the absence  of internal  errors,  the device  may 
detect a condition  where  it cannot  meet the host’s  expectation  for data transfer,  as indicated  by the Direction 
bit  of  the  bmCBWFlags  field  and  the  dCBWDataTransferLength  field  of  the  CBW.  In  some  of  these  cases, 
the  device  may  require  a  reset  to  recover.  In  these  cases,  the  device  shall  return  Phase  Error  status 
(bCSWStatus  = 02h). 
 
 
 
6.4.4.6.4 
Command Failure 
After  recognizing  that  a  CBW  is  valid  and  meaningful,  the  device  may  still  fail  in  its  attempt  to  satisfy  the 
command.  The device shall report this condition by returning  a Command  Failed status (bCSWStatus  = 01h).