Marley Engineered Products D 사용자 설명서

다운로드
페이지 4
4
another heater, it is easier for the power supply connections to be made prior
to the installation of the heater(s) to the wall. If this is not possible, connections
may be made through the opening in the junction boxes when the front cover(s)
is removed. See Figure 8.
5. Connecting power supply cables may be routed from heater to heater by drilling
a 1/2-inch (13mm) diameter hole in the end caps for the heaters that fit togeth-
er.    See  Figure  9.    To  prevent  possible  damage  to  internal  heater  wiring,  all
drilling of end caps must be done with end caps removed from heater.
6. Wire heaters as shown in Wiring Diagram, Figure 10.
7. Replace the front covers and end caps according to “Installation of Single Unit”,
Steps 12 and 13.
OPERATING AND MAINTENANCE INSTRUCTIONS
1. An integral or remote wall thermostat is recommended for each room. In very
large  rooms  it  is  recommended  that  a  low  voltage  thermostat  with  double  or
multiple circuit relays be used to provide the most comfortable results.
DO LOCATE
DO NOT
THERMOSTAT
LOCATE THERMOSTAT
• A minimum of two feet
• Near televisions or 
(61cm) from any 
appliances that emit heat.
outside wall.
• Near drafts from an
• Approximately five feet
open doorway.
(1,5m) from the floor,
• Where it would be struck 
preferably on an inside 
by direct rays of sunlight.
wall location.
2. After  the  baseboard  system  has  been  completely  installed,  all  thermostats
should be turned to LOW or NO HEAT setting. Then turn on breakers or install
fuses. Wait 3 to 5 minutes and check to see that none of the heaters are oper-
ating.  If  operating,  disconnect  power  and  check  wiring.  If  none  are  operating
then turn the thermostats to highest setting and wait 3 to 5 minutes. Check to
see  that  all  heaters  are  operating.  Should  any  not  be  operating,  disconnect
power and check wiring.
3. Allow entire system to operate steadily for 1/2-hour. For a period of time after
the heaters are put into operation, the owner may notice a “new smell” coming
from the heaters. This is expected on new installations. Bringing heaters to full
operation will eliminate this condition in a short period of time.
4. Select the setting for comfort on all thermostats.
5. To clean heater: Because of the convection heating principle which depends
upon circulation of air through the finned element, dust particles will periodical-
ly be deposited between the fins and should be removed occasionally for max-
imum efficiency of the heater. A vacuum cleaner with proper attachments can
easily be worked along the top and bottom of the finned element to clear it of
dust deposits.
NOTE: The painted finish of the heater may be cleaned with a slightly damp
cloth if desired. Do not use wax cleaners or polishes as these waxes may
vaporize when the heater is in operation and cause discoloration.
UNE FOIS LES CONNEXIONS 
EFFECTUÉES, REPOUSSEZ LES 
CÂBLES DANS LA BOÎTE DE 
JONCTION.
Figure 8. Wiring Through Junction Box Opening
FRONT OF 
HEATER
1
15
/
32
"
(37mm)
1
/
2
" DIA.
(13mm)
3"
(76mm)
Figure 9. End Cap Drill Pattern
LIMIT
ELEMENT
LIMIT
ELEMENT
TWO HEATERS ON ONE SUPPLY
POWER SUPPLY
Figure 10. Dual Heater Wiring Connections
WIRING DIAGRAM
HOW TO ORDER REPAIR PARTS
In order to obtain any needed repair or replacement
parts,  warranty  service  or  technical  information,  please
contact Marley Engineered Products Service Center toll-
free by calling  1-800-642-HEAT. 
When ordering repair parts, always give the informa-
tion listed as follows:
1. The Part Number 
2. The Model Number 
3. The Part Description
4. Date of Manufacture
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against
defects in workmanship and materials for one year from date of installation, except
heating elements which are warranted against defects in workmanship and materi-
als for ten years from date of installation. This warranty does not apply to damage
from accident, misuse, or alteration; nor where the connected voltage is more than
5% above the nameplate voltage; nor to equipment improperly installed or wired or
maintained in violation of the product’s installation instructions. All claims for war-
ranty work must be accompanied by proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstal-
lation of products, including labor costs, and shipping costs incurred to return prod-
ucts  to  Marley  Engineered  Products  Service  Center.Within  the  limitations    of  this
warranty, inoperative units should be returned to the nearest Marley authorized ser-
vice center or the Marley Engineered Products Service Center, and we will repair
or replace, at our option, at no charge to you with return freight paid by Marley. It is
agreed  that  such  repair  or  replacement  is  the  exclusive  remedy  available  from
Marley Engineered Products.
THE  ABOVE  WARRANTIES  ARE  IN  LIEU  OF  ALL OTHER  WARRANTIES
EXPRESSED  OR  IMPLIED.  AND  ALL IMPLIED  WARRANTIES  OF  MER-
CHANTABILITY AND  FITNESS  FOR  A PARTICULAR  PURPOSE  WHICH
EXCEED  THE  AFORESAID  EXPRESSED  WARRANTIES  ARE  HEREBY DIS-
CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED
PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARIS-
ING  WITH  RESPECT TO  THE  PRODUCT,  WHETHER  BASED  UPON  NEGLI-
GENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above exclusion or limitation may not apply to you. This warranty
gives you specific legal rights, and you may also have other rights which vary from
state to state.
For  the  address  of  your  nearest  authorized  service  center,  contact  Marley
Engineered  Products,  in  Bennettsville,  SC,  at  1-800-642-4328.  Merchandise
returned to the factory must be accompanied by a return authorization and service
identification tag, both available from Marley Engineered Products. When request-
ing return authorization, include all catalog numbers shown on the products.
SWO 315
5200-2083-004
09/97
SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA