d. Locate the two (2) latches at the top of the 
control  compartment.  To  disengage  the  two 
latches from the bottom vee-flange of the glass 
enclosure panel, reach for the handles located 
towards the back of the latches and pull the 
handles down toward the front of the unit.  See 
Figure 63 on page 34.
e. Swing the bottom of the door out and raise 
it slightly to lift the top flange of the door frame 
away from the appliance.
Step 2. Carefully remove the log set. Exercise 
care as not to break the log set.
Step  3.  Referring  to  Figure  67,  remove  the  
burner.
FRONT OF FIREPLACE
PAN BURNER
VENTURI TUBE ARM
AIR SHUTTER
ADJUSTMENT LEVER
FIREBOX SUBFLOOR
Figure 67
Millivolt Appliances
Step 4.  Refer to Figure 68 and the instruc-
tions provided with the kit.  Using a Torx T20, 
remove and discard the three pressure regulator 
mounting screws.  Remove the pressure regu-
lator, spring, poppet, diaphragm and bushing.  
Discard  all  removed  components.    Ensure 
the rubber gasket installed on the back of the 
replacement  pressure  regulator  is  properly 
positioned and install the new pressure regula-
tor using the new screws supplied with the kit.  
Tighten screws to 25 In. lb. torque.
Spring
Adjusting
Screw
Slotted
Cap
PSI
OFF
I
ON
CONTROL
IGNITE
Manifold
Pressure
Test Port
Inlet Pressure Test Port
Pressure
Regulator
Remove
These
Components
Pilot
Orifice
Retaining
Clip
Ignitor
Assembly
Pilot
Assembly
Pilot
Orifice
Flare Nut
All Models
Step 8.  (Refer to Figure 67 )
A. Remove  the orifice from the manifold and 
replace  it  with  the  one  provided  in  the  kit. 
The  following  table  shows  the  orifice  sizes 
for  natural  and  propane  models.  Figure  72 
illustrates the orifice.  Always check and verify 
correct orifice size.
When reinstalling the ignitor assembly, use 
extreme care to prevent damage and break-
age.  Do not apply any leverage to the ignitor 
assembly while restoring the retainer clip to 
its original position.
Note: If the ignitor is damaged, a replacement kit 
is available, order Catalog No. 87L54.
Electronic Appliances
Step  7.  Honeywell  Electronic  Valves  -  See 
Figure 70 and the instructions provided with 
the kit.  Remove the slotted cap screw, o-ring, 
pressure-regulating adjusting screw and spring.  
Retain all parts for possible later use.  Install 
new components from the kit. Black cap and 
red  spring  for  propane  gas  units.  Silver  cap 
and stainless steel spring for natural gas units. 
Before installing the cap, attach manometer to 
the manifold side pressure test fitting and adjust 
screw until pressure reads 3.5 inches water col-
umn (0.87 kPa) for natural gas, and 10.0 inches 
water column (2.49 kPa) for propane gas.
See Figure 71 and replace the pilot orifice as fol-
lows:  Remove the ignitor assembly retainer clip, 
and carefully remove the ignitor assembly.
Exercise extreme care to prevent damage to 
or breakage of the ignitor assembly
Remove the screw securing the pilot assembly 
to its mounting bracket.  Back off the flare nut 
at the end of the pilot gas line to free the pilot 
assembly from the gas line.  Remove the pilot 
orifice and replace it with the one provided with 
the conversion kit.  Reinstall the pilot assembly 
by reversing the steps detailed here.  
Step 5. Attach manometer to the manifold side 
pressure test fitting and verify manifold pres-
sure reads 3.5 inches water column (0.87 kPa) 
for natural gas, and 10.0 inches water column 
(2.49 kPa) for propane gas.
Step 6.  Refer to Figure 69 and remove the 
pilot hood assembly to access the hexed pilot 
orifice.  Remove and replace the orifice with the 
one provided with the kit.