Regency U32S-LP5 사용자 설명서

다운로드
페이지 36
28
U32S-5 FPI Direct Vent Gas Insert
1)  Turn the unit off and allow it to cool down to room temperature.
2)  Disconnect the power source and turn off the gas supply to the
 insert.
3)  Open the bottom louver.
4)  Remove the door frame by lifting out from the bottom and lift up off 
the glass door.
5)  Remove the glass door.
 
a)  Remove the 2 hooks shown below at the bottom of the glass  
 
     door
 b) 
 
Swing the door out 45
o
 from the bottom and lift up and  
 
      out.
6)  Remove the burner by undoing the 2 screws shown. Carefully  slide 
the burner to the left.  Then lift the burner up and out ensuring not to 
spill glass crystals.
7)  Carefully set aside the burner and glass crystals.
Door Frame
Glass Door
Burner
VALVE ASSEMBLY REPLACEMENT
8)  Remove the base cover by lifting up from the back and maneover 
out.
Base Cover
9)  Disconnect the ON/OFF connector wires from the valve.
 
NOTE: For LP units disconnect the DC Sparker ignitor wire from the 
valve.
ON/OFF Wires
MAINTENANCE