Installation and Operating Instructions
 
Downflow Fan Heater 
 
 
 
 
 
 
 
 
 
 
 
            08/30041/1       Issue 1
Model  FX 20VL   
 
 
 
 
 
 
 
 
 
 
(IP22)   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Dimensions 
 
(millimetres) 
 
 
 
 
 
Model(s) Specification 
 
 
 
FX 20VL
 
(Low Level) 1/2kw + Adjustable Thermostat (external by installer) 
 
 
 
 
 
 
 
 
 
 
 
 Fig. 
1
 
 
 
 
 
 
 
 
 
 
SUPPLY CABLE IS NOT SUPPLIED WITH THIS APPLIANCE AND IT 
SHOULD THEREFORE BE INSTALLED BY A COMPETENT 
ELECTRICIAN IN ACCORDANCE WITH THE IEE REGULATIONS. 
 
 
 
 
 
 
 
The Controls
 
 
 
 
The cut-out is a safety device which switches off the heater and fan if for 
any reason the appliance overheats. (see ‘Safety’) 
 
 
 
 
The thermal fuse link is provided as an added safety feature, and 
 
 
operates to open circuit if there is abnormal overheating within the 
appliance. The operation of these safety devices is described under 
‘Safety’ 
 
 
 
 
This model is also fitted with an adjustable thermostat which can be 
adjusted by user. This has the following settings : 0, * (frost protection), 1, 
2, 3, 4, 5 (max). The thermostat should be set to 5 (max). Once the 
required room temperature is reached, it can be turned back until a click 
(switch off) can be heard, which will give you a constant room temperature 
with the thermostat switching on and off automatically. This gives you an 
approximate room temperature range of 7°C - 32°C depending on room 
size. Frost protection : When the temperature falls below + 5 … +8°C, the 
appliance switches on automatically.  
 
 
 
 
 
 
 
 
 
 
Note – On this model the thermostat works independent from the selected 
output. 
 
 
 
 
To reset the selector switch first remove the top cover, then adjust 
thermostat to required setting, or reset selector switch to 1kw or 2kw as 
required, then refit top cover. 
 
 
 
 
 
 
 
 
IMPORTANT SAFETY ADVICE 
 
WARNING  - DO NOT USE THIS HEATER IN THE IMMEDIATE  
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
 
THIS APPLIANCE CARRIES A WARNING ‘DO NOT COVER’ TO 
ALERT THE USER TO THE RISK OF OVERHEATING THAT EXISTS 
IF THE APPLIANCE IS ACCIDENTALLY COVERED. 
 
DO NOT COVER THE APPLIANCE  or place material or garments 
on it, or obstruct the air circulation around this appliance, for 
example with curtains or furniture, as this could cause 
overheating and a fire risk. 
 
DO NOT PLACE AEROSOLS OR OTHER CONTAINERS 
SUSCEPTIBLE TO HEAT IN THE DIRECT AIRFLOW FROM THE 
UNIT. 
 
THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A 
FIXED SOCKET OUTLET. 
 
WARNING – DISCONNECT THE HEATER FROM THE ELECTRICITY 
SUPPLY BEFORE UNDERTAKING SERVICE OR REPAIR. 
 
WARNING – If the appliance is fitted in a bathroom, a cable outlet 
will be necessary with the supply to the unit controlled by a 
double pole switch. The switch if inside the bathroom should be 
pull cord operated and if outside should be adjacent to the 
entrance door. The appliance must be mounted so that no part of 
it can be touched by any person using bath or shower. 
 
THIS HEATER MUST NOT BE OPERATED WITHOUT THE COVER 
CORRECTLY IN POSITION. 
Safety 
General 
 
 
Cut-Out 
 
For your safety, this appliance is fitted with a thermal cut-out. In the event 
that the product overheats, the cut-out switches the heater off 
automatically. 
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND 
RETAINED FOR FUTURE REFERENCE
 
To bring the heater back into operation, remove the cause of overheating, 
then turn off the electrical supply to the heater for a few minutes. 
 
The heater has a loading of 2KW. It is designed for permanent wall 
mounting and is suitable for operation on A.C. electricity supply having the 
same voltage as shown on the rating label. 
When the heater has cooled sufficiently reconnect and switch on the 
heater. 
 
 
The heater is fitted with an internally mounted selector switch which on 
installation of the heater allows a choice of 1kW or 2kW output to suit the 
dimensions of the room to be heated. 
 
Fuse Link 
A thermal fuse link is provided as an added safety feature. If the fuse link 
operates and opens circuit it is the result of abnormal overheating within 
the appliance, and servicing of the appliance by a competent service 
engineer will be required in order to ensure the future safe operation of the 
heater. Dimplex Customer Services should be contacted, who will arrange 
the replacement of any faulty parts and the fitting of a new fuse link.  
 
In rooms of less than 9 – 11 cubic m. (350 - 400 cubic ft.) 1kW output 
should be selected, otherwise nuisance tripping of the thermal overload 
cut-out may occur. 
 
 
NOTE : THE SWITCH HAS BEEN FACTORY SET FOR 2kW 