Unibrain 630 사용자 설명서

다운로드
페이지 73
Unibrain Fire-i 530/630/830 Operation Manual 
Page 28 
 
 
 
 
 
 
 
3.9.4.  Trigger Mode 0 
The  Camera starts integration of the incoming light from the  external trigger input falling edge. The  Integration 
time is described in the "Shutter" register. No parameter is needed.     
 
3.9.5.  Trigger Mode 1   
The camera starts the integration of the incoming light from the external trigger input falling edge. The integration 
time is equal to the low state time of the external trigger input. No parameter is needed.     
 
3.9.6.  Trigger Mode 2   
The  camera starts the  integration of incoming light from the  first external trigger input falling edge. At the N-th 
(parameter) external trigger input falling edge, the integration will be stopped. A parameter is required and shall be 
two or more.    (N >= 2).