Between touches with different polarity  
1000VAC 1minute  
Between touch and winding  
1000VAC 1minute  
Surge voltage  
Between touches with same polarity  
1500V (10×160us)  
Length of open time  
3ms max  
Length of closed time  
3ms max  
Longevity  
Mechanical  
50×106 times (3Hz)  
Electrical  
200×103 times (0.5Hz)  
Temperature  
-40℃ ~  +70℃  
RS232 
RS232 port is reserved for technical support diagnosis and upgrade.  
RS485 
When the DVR receives a  camera control command, it transmits that 
command up the coaxial cable to the PTZ device. RS485  is a single-
direction protocol; the PTZ  device cannot return any data to the unit.  To 
enable the operation, connect the PTZ device to the RS485 (A,B) input on 
the DVR. Se
. 
Since RS485 is disabled by default for each camera, you must enable the 
PTZ settings first. This  series DVRs  support  multiple protocols such as 
Pelco-D, Pelco-P.  
To connect PTZ devices to the DVR: 
1.  Connect RS485 A,B  on the DVR rear panel. 
a. Ensure the decoder has the same  grounding with the DVR, 
otherwise you will not be able to control the PTZ. Shielded twisted wire 
is recommended, and the shielded layer should be used to connect the 
ground. 
b.  Avoid  high voltage. Ensure proper wiring and some thunder 
protection measures. 
c. For signal wires that are 
too long, 120Ω should be connected parallel 
between A, B lines on the far end to reduce reflection and guarantee 
signal quality.