Honeywell HD-DVR-1004 사용자 설명서

다운로드
페이지 182
Overview of Navigation and Controls 
 
54 
PTZ Setup 
Note 
The camera video should be in the current screen. 
Before setup, check whether the following connections 
are right: 
•  PTZ and decoder connection  
•  Decoder address setup 
•  Decoder A  (RS485 +) /  B  (RS485  -)  line connects with 
DVR A/B line 
Boot up the DVR, and input the user name and password. 
In the main menu, select Setting
Pan/Tilt/Zoom. The interface is shown 
as in 
. Here you can set the following items: 
• 
Channel:  Select the channel
  connected with the speed dome video 
port.
 
• 
Protocol: Select the corresponding PTZ protocol (such as PELCOD). 
• 
Address: 
Identical to the device address set in the speed dome. 
Default address is 1. 
• 
Baud rate:  Select corresponding baud rate. 2400 for Pelco-D 
protocol. 
• 
Data bits: Select corresponding data bits. Default value is 8. 
• 
Stop bits: Select corresponding stop bits. Default value is 1. 
• 
Parity: There are three options: Odd/Even/None. The default  value 
is none.