Figure 3-2 Sample of Alarm Input (Normal Close Type) 
 
Alarm Output Port 
  Three ways to relay alarm output (NO contact). External power supply 
is needed for external alarm device. 
  To avoid overloading, please read the following relay parameters sheet 
carefully. 
  6 ways relay alarm output (NO contact). Provide external power to 
external alarm device. 
  For controllable +12V, it can be used to provide power to devices such 
as reset smoke sensor. 
Table 3-1 Relay Specification: 
Model JRC-27F 
Material of the touch  
Silver  
Rated switch capacity  
30VDC 2A, 125VAC 1A  
Maximum switch power  
125VA 160W  
Maximum switch voltage  
250VAC, 220VDC  
Rating (Resistance 
Load)  
Maximum switch currency  
1A  
Between touches with same 
polarity  
1000VAC 1minute  
Between touches with 
different polarity  
1000VAC 1minute  
Insulation  
Between touch and winding   1000VAC 1minute