6. MISCELLANEOUS 
 
6.1 RS-232 & RS-485 Setup & Protocol 
 
6.1.1 RS232 & RS485 Setup 
 
Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 exchanged, 
see pin configuration chart below for details) to connect the COM 1 on the rear panel of the 
DVR to a PC. 
 
 Set 
the RS-232 option to ON in the COMMUNICATION page of the setup menu. 
 
Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit. 
 
6.1.2 Communication Protocol 
 
 
 
6.1.2.0 General Command Format 
<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, 
{<Number of parameters>, <Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f> 
 
 
 
 
   
     Lead Code  = 0x41 
Dest ID     = 0x01 
Src ID     = 0x20 
   
     Main Category  = 0x01   Keys and Signals 
 
 
           
   
= 0x02   Command 
             Second Category   = 0x01 Handshake 
   
 
                
= 0x02 Request Time/Set Time 
 
    
 
 
 
 
  = 
0x06 
Request 
System 
State 
 
    
 
 
 
 
  = 
0x0b 
Time 
Search 
 
    
 
 
 
 
  = 
0x10 
Request 
HDD 
Info 
 
    
 
 
 
 
  = 
0x11 
Request 
REC 
Position 
 
    
 
 
 
 
  = 
0x12 
Playback 
Immediately 
   
     End Code= 0x4f 
 
          The different command types and their corresponding parameters are as follows: 
 
 
6. MISCELLANEOUS