Maxtor SLD240 사용자 설명서

다운로드
페이지 77
72 
 
12.2 Communication Protocol 
 
IMPORTANT:  This section is designed to allow users to control the DVR via the RS -232 and 
RS-485 ports.  The following information is intended to be used by qualified professionals.  
Do not make any changes to your system’s settings unless instructed by a qualified 
technician. 
 
 
12.2.0 General Command Format 
<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, {<Number 
of parameters>,<Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f> 
 
 
 
 
 
     Lead Code    = 0x41 
Dest ID     = 0x01 
Src ID     = 0x20 
 
 
     Main Category   
= 0x01   Keys and Signals 
 
 
        
= 0x02   Command 
               Second Category   
= 0x01 Handshake 
 
 
 
              
 
= 0x02 Request Time/Set Time 
 
 
 
 
        
= 0x06 Request System State 
 
 
     End Code= 0x4f 
 
      The different command types and their corresponding parameters are as follows: 
12.2.1 Keys and signals 
 
 
PC Send: <0x41>, <0x01>, <0x20>, <0x01>, <Key Value>, <0x4f> 
 
 
< The value of a specific front panel key > 
 
KEY_PLAY 
   
 
 
 1 
 
 
KEY_STOP 
  
 
 
 3 
 
 
KEY_PAUSE        
        4 
 
 
KEY_POWER   
 
 
 5 
 
 
KEY_REC  
 
 
 
 6 
 
 
KEY_SETUP 
 
 
  
 7 
 
 
KEY_ENTER 
 
 
 
 8 
 
 
KEY_SEARCH   
 
 
10 
 
 
KEY_DISPLAY   
 
 
11 
 
 
KEY_UP   
 
 
 
13 
 
 
KEY_DOWN 
 
 
 
14 
 
 
KEY_LEFT 
 
 
 
15 
 
 
KEY_RIGHT 
 
 
 
16 
 
 
KEY_MONITOR  
 
 
36