Panasonic ag-hpx300p 사용자 설명서

다운로드
페이지 166
1
Chapter

Adjustments
and
Settings
for
Recording
Setting the Electronic Shutter
Setting the Shutter Mode and 
Speed
1
PresstheSHUTTERswitchpositionedatOFF
towardsON.
SHUTTERswitch
2
PresstheSHUTTERswitchtowards[SEL].
Repeatthisswitchoveruntilthedesiredmode
orspeedappearsintheviewfinderscreen.
•  If all modes and speeds are available, the display 
changes in the following order:
For0iand0Precording
(1/15) (1/30) 1/60 1/100
1/250
S/S
1/120
1/500 1/1000 1/2000
For0Precording
(1/7.5) (1/15) 1/60 1/100
1/250
S/S
1/120
1/500 1/1000 1/2000
ForPrecording
(1/6) (1/12) 1/60 1/100
1/250
S/S
1/120
1/500 1/1000 1/2000
•  The bracketed (  ) speeds cannot be selected 
when VFR is ON.
 NOTE
•  In any electronic shutter mode, a slower shutter speed will 
reduce camera sensitivity.
•  In auto iris mode, a faster shutter speed will increase the 
aperture and lower the depth of field.
•  Changes in synchro scan and shutter speed settings may 
cause screen flicker.
•  Under fluorescent lighting and other discharge lighting 
systems, horizontal stripes may appear on the screen. 
Changing the shutter speed may correct this problem.
•  A subject that is captured when moving quickly across the 
field of view may appear distorted. This is due to the signal 
read out format of the image sensor (MOS sensor) and is not 
a malfunction.
•  The red, blue and green dots that may appear on the screen 
at low shutter speeds do not indicate a malfunction.
Viewfinder displays relating to the shutter
See [Vie wfinder Screen Status Displays] (page 65).
Placing the Camera-recorder in 
SYNCHRO SCAN Mode
To place the camera-recorder in SYNCHRO SCAN mode, 
follow the steps below.
1
PresstheSHUTTERswitchpositionedatON
towardsSEL,toplacethecamera-recorderin
SYNCHROSCAN(S/S)mode.
SHUTTERswitch
SYNCHROSCANswitch
2
InSYNCHROSCANmode,usetheSYNCHRO
SCANswitchtomakesteplesschangesinthe
rangebetween1/0.0sand1/.s(for0i
mode).
•HolddowntheSYNCHROSCANswitchtospeed
uptherateofshutterspeedchanges.
Ifshutterspeedchangesstopbeforethedesired
shutterspeedhasbeenreached,pressagainto
continuechangingshutterspeeds.
Range of variation in each mode
•  60P/60i mode: 1/60.0 to 1/249.8
•  30P/30PN mode: 1/30.0 to 1/249.8
•  24P/24PA/24PN mode: 1/24.0 to 1/249.8
•  When the SYNC SCAN DISP option in DISPLAY SETUP is 
set to deg: 3.0d to 359.5d
•  If SYSTEM MODE setting is changed, shutter speed may 
also be changed.
SettingthemenuoptionSYNCSCANDISPintheDISPLAY
SETUPscreentodegprovidesaguidetosettingand
displayingshutterangle.