Wegener Communications DVR395 사용자 설명서

다운로드
페이지 30
  
Page 
21 
 
Page 21 of 30 
DVR395/DVR396-002 
The following definitions apply to 
Table 6
Blink   - LED is OFF for 1 second, and then blinks on count times (ON for 250 ms  
 
   and OFF for 250 ms). This overall pattern is continued. 
Flutter  - ON for 50 ms, OFF for 50 ms, repeating…. 
AMBER - RED and GREEN turned ON at the same time. 
Note:  ms = 1/1000 second 
The conditions are listed in the order of their display priority with highest priority at top. For 
example, if the unit is in Satellite Search Mode, and there is an NTSC/PAL mismatch, the LED 
should indicate the Satellite Search condition. 
Note that the alarm conditions are those conditions preventing the delivery of video. 
2.5 POWER 
ON 
PROCEDURE 
Apply power to the receiver. The unit performs a quick checksum test on the EEPROM 
(electrically erasable programmable read only memory). When the test passes, the unit initializes 
various devices and configures itself according to the EEPROM settings. It then waits for the 
receiver board to complete its power up test, which takes about 10 seconds. When the receiver 
board passes its test, the IRD sends a tune request to the receiver board and the Welcome 
Banner, shown in 
Figure 6
 (Page 21), to the serial port.  If you are in Terminal mode, the banner 
displays on the terminal screen.  Otherwise, “ALARM: INSTALLATION” displays on the 
monitor screen.  The IRD then enters alarm mode until all of the alarm conditions are cleared. 
X.X is the application code's version number.  The text at the bottom of the screen is shown only 
if the serial device is set to Terminal mode. 
 
 
 
 
 
 
Figure 6.  Welcome Banner 
Figure 7.  Failure Banner 
 
* These screens are available in units with firmware versions 2.0 and above. 
 
 
Wegener Communications Copyright 1997 
MPEG 2 Integrated Receiver Decoder 
Firmware Version x.x 
 
 
 
EEPROM Failure 
Receiver Board Diagnostics Failure 
Receiver Board Communications Failure