Nikon DSR-1500AP 사용자 설명서

다운로드
페이지 112
100
Troubleshooting
Chap
ter
 6
   Maint
ena
nc
e and
 T
roub
les
h
o
o
ting
Error Messages
This unit is provided with a self-diagnostic function that 
detects internal abnormalities. When it detects an 
abnormality, it outputs an error message to the monitor 
screen and indicates an error code in the time counter 
display.
Note
To display error messages on the monitor screen, connect 
the monitor to the B
−Y/CPST (SUPER) connector, and set 
the CHARA. DISPLAY menu item (see page 61) to ON 
(factory default setting).
If an error message appears, follow the direction indicated 
on the monitor screen.
Alarm Messages
When operating this unit, the unit may sometimes output 
alarm messages such as the one shown below to the 
monitor screen and the time counter display.
If such an alarm message appears, a connection or 
operation error may have been made, or condensation on 
heads may have occurred. Follow the direction indicated 
on the monitor screen.
Note
To display alarm messages on the monitor screen, it is 
necessary for the monitor to be connected to the B
−Y/
CPST (SUPER) connector, and set the following menu 
items to ON.
• CHARA. DISPLAY (see page 61)
• ALARM (see page 62)
• REF ALARM (see page 62)
Error02-603
ERROR
AN ERROR HAS BEEN
DETECTED. INFORM SERVICE
OF FOLLOWING CODE:
02-603
PRESS EJECT KEY
TO EJECT TAPE.
Time counter display
Error message
Error code
Direction
Error code
Monitor screen
REMOTE!
ALARM
REMOTE MODE IS SELECTED.
SET REMOTE/LOCAL SWITCH
TO LOCAL.
Monitor screen
Time counter display
Direction
Cause of 
alarm