Safety and Homologation Statements 
Lithium Batteries - Page 57 
IP Office Installation Manual 
Safety and Homologation Statements - Page 57 
40DHB0002USCL – Issue 9 (28th October 2003) 
Lithium Batteries 
Safety and Homologation Statements 
CE Mark 
The "CE" mark affixed to this equipment means that the unit complies with the 1999/5/EC 
(R&TTE), 89/336/EEC (EMC) and 72/23EEC (LVD) Directives 
Declaration of Conformity 
The Declaration of Conformity (DoC) for the IP400 Office products is contained with in the 
CD accompanying the products. 
 
This warning symbol is found on the base of IP401, IP403, IP416 and IP412 
units and on the base of the IP400 Digital Station 80W Lump-in-Line PSU (see 
page 24). Refer to page 59 for information concerning which Trunk Interface 
module variants are fitted in which country. 
WARNING 
The Avaya IP400 Office units are intended to be installed by 'Service Personnel' and 
it is the responsibility of the Service Personnel to ensure that all subsidiary 
interconnected equipment is wired correctly and also meet the safety requirements 
of IEC60950 or UL60950 where applicable. 
 
Lithium Batteries 
A lithium battery is fitted to the real time clock on the IP401/403/406 and IP412 mother 
boards. 
WARNING 
The Lithium battery must only be replaced by Avaya personnel or authorized 
representatives. There is a danger of explosion if the battery is incorrectly replaced. 
Replace only with the same or equivalent type recommended by the manufacturer. 
Dispose of used batteries according to the manufacturer's instructions. 
 
Lightening Protection/Hazard Symbols 
Lightening protectors  
The buildings lightening protectors must be verified as follow: 
1.  Check the lightening protectors, at the trunk cable entry point to the building housing 
the Avaya IP Office, paying special attention to the lightening protection grounding. 
Report any problems, in writing, to the telephone company. 
2.  Equipment that is designed to be connected using internal wiring is typically not 
lightening protected. Hence, Avaya IP Office extension cabling must not leave the 
building.
 For installations where telephones and/or other standard (tip/ring) devices 
are installed in another building then lightening protection is required (see page 36). 
 
Hazard Symbol  
The shock hazard symbol is intended to alert personnel to electrical hazard or 
equipment damage. The following precautions must also be observed when 
installing telephone equipment: 
1.  Never install telephone wiring during a lightening storm. 
2.  Never install telephone jacks in wet locations unless the jack is specifically designed 
for wet locations. 
3.  Never Touch uninsulated telephone wires or terminals unless the telephone line has 
been disconnected at the network interface. 
4.  Always use caution when working with telephone lines.