Polycom 1725-11530-310 사용자 설명서

다운로드
페이지 373
 Configuration Files
A - 65
call.dialtoneTimeOut
Null, positive 
integer
60
Time in seconds to allow the dialtone to be 
played before dropping the call. 
If set to 0, the call is not dropped.
If set to Null, call dropped after 60 seconds.
call.lastCallReturnString
string of 
maximum 
length 32
*69
The string sent to the server when the user 
selects the “last call return” action.
call.callsPerLineKey
1 to 24 OR
1 to 8
24 OR
8
For the SoundPoint IP 600, 601, and 650, the 
permitted range is 1 to 24 and the default is 24. 
For all other phones the permitted range is 1 to 8 
and the default is 8.
This is the number of calls that may be active or 
on hold per line key on the phone.
Note that this may be overridden by the 
per-registration attribute of 
reg.x.callsPerLineKey
. Refer to 
 on page 
call.stickyAutoLineSeize
Null, 0, 1
0
If set to 1, makes the phone use "sticky" line 
seize behavior. This will help with features that 
need a second call object to work with. The 
phone will attempt to initiate a new outgoing call 
on the same SIP line that is currently in focus on 
the LCD (this was the behavior in SIP 1.6.5).
If set to 0 or Null, the feature is disabled (this was 
the behavior in SIP 1.6.6).
Note: This may fail due to glare issues in which 
case the phone may select a different available 
line for the call.
call.stickyAutoLineSeize.
onHookDialing
Null, 0, 1
Null
If call.stickyAutoLineSeize is set to 1, this 
parameter has no effect. The regular 
stickyAutoLineSeize behavior is followed.
If call.stickyAutoLineSeize is set to 0 or Null 
and this parameter is set to 1, this overrides the 
stickyAutoLineSeize behavior for hot dial only. 
(Any new call scenario seizes the next available 
line.) 
If call.stickyAutoLineSeize is set to 0 or Null 
and this parameter is set to 0 or Null, there is no 
difference between hot dial and new call 
scenarios.
Note: A hot dial occurs on the line which is 
currently in the call appearance. Any new call 
scenario seizes the next available line.
Attribute
Permitted 
Values
Default
Interpretation