Mitsubishi Electronics QD75MH1 사용자 설명서
9 - 39
MELSEC-Q
9 MAJOR POSITIONING CONTROL
9.2.5 4-axis linear interpolation control
In "4-axis linear interpolation control" ("
Da.2
Control system" = ABS linear 4, INC
linear 4), four motors are used to carry out position control in a linear path while
carrying out interpolation for the axis directions set in each axis.
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)
carrying out interpolation for the axis directions set in each axis.
(Refer to Section 9.1.6 "Interpolation control" for details on interpolation control.)
[1] 4-axis linear interpolation control (ABS linear 4)
In the absolute system 4-axis linear control, using an address established by a
machine OPR in the 4-axis coordinate space, a linear interpolation positioning is
carried out from the current stop position (start point address) to the address (end
point address) set in the "
machine OPR in the 4-axis coordinate space, a linear interpolation positioning is
carried out from the current stop position (start point address) to the address (end
point address) set in the "
Da.6
Positioning address/movement amount".
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning control.
machine will immediately stop if the error is detected during a positioning control.
•
When the movement amount for each axis exceeds "1073741824 (=2
30
)"
An "outside linear movement amount range error (error code: 504)" will occur at
the positioning start.
(The maximum movement amount that can be set in "
the positioning start.
(The maximum movement amount that can be set in "
Da.6
Positioning
address/movement amount" is "1073741824 (=2
30
)".)