Avaya 700217243 사용자 설명서

다운로드
페이지 106
 2 Installing Your System
10
Installing the Control Unit
Quick Reference Guide
Wall-Mounting a 5-Slot Carrier and Modules 
Install the 5-slot carrier within 5 feet (1.5 meters) of a properly grounded wall 
outlet (not controlled by a switch) and the network interface jacks. When you 
mount the carrier on the wall, leave at least 1 foot (0.3 meter) of clearance at the 
top and sides and 2 feet (0.6 meter) at the front and bottom to ensure proper 
ventilation. 
Follow these steps to wall-mount the 5-slot carrier and modules:
1
Using the enclosed template, mark the screw locations on the wall. If you 
are mounting the carrier on plywood, start four #12 screws supplied with the 
carrier, leaving the screw heads extending approximately 1/4 inch (0.64 cm) 
from the wall. If you are mounting on drywall, use wall anchors, which must 
be purchased separately.
2
Before installing any modules, make sure the clear, plastic protector has 
been removed from the connector area on the rear of each module. To 
remove the protector, grasp the tabs on the ends of the protector and lift.
3
Insert the PARTNER ACS processor module in the center slot of the carrier. 
4
In the other slots, from left to right, first install the 1600 DSL module (if 
used), then the 012E, 308EC, or 206 modules, followed by the 400 or 200 
modules and/or a PARTNER Messaging or PARTNER MAIL VS module. 
Align the module carefully in the appropriate slot. For proper engagement of 
the connectors, the module must be inserted straight into the carrier. Once 
the module is properly seated, firmly push the center of the module until the 
connectors on the module lock into place. A slight click indicates the 
connectors are engaged.
The location of each module within the carrier is important; place the 
modules as instructed in the following procedure.