Multimedia communications products: MMCX, MMCH, 
ESM
555-233-116
222
Issue 4   October 2002 
Figure 62.
Typical multimedia call handling ESM connections
ESM installation
Use the following procedure and 
 to connect to the ESM equipment:
1. Install the TN2207 primary rate interface (PRI) circuit pack and the 
TN787F/G/H/J/K multimedia interface (MMI) circuit pack in the port carrier.
2. Record the circuit pack locations.
3. Connect the ESM Y-cable as shown.
Administration
1. Enter list configuration all, and a list of the installed carriers, circuit 
packs, and ports appears.
2. Record the location (board number) of the new circuit packs and verify that 
all other required circuit packs (refer to 
) are present.
3. Enter add DS1 xxxxx, (where xxxxx is the location of the TN2207 PRI 
circuit pack recorded in step 2), and the DS1 circuit pack administration 
form appears.
4. Set the 
Name:
 field to ESM DS1
5. Set the 
Bit Rate: 
field to 2.048
6. Set the 
Line Coding:
 field to hdb3
7. Set the 
Signaling Mode:
 field to isdn-pri
8. Set the 
Connect:
 field to pbx
1. Port B Y-cable connector to a TN787 
multimedia interface (MMI) circuit pack
2. Port A Y-cable connector to a TN2207 PRI 
circuit pack 
3. 25-pair Y-cable
4. 357A adapter
5. D8W cord connected to 357A adapter 
S/B port 8
6. Expansion service module (ESM)
7. Port B on compatible primary rate 
interface (PRI) card