Avaya 555-233-116 사용자 설명서

다운로드
페이지 246
Data modules and asynchronous data units
555-233-116
52
Issue 4   October 2002 
5. Use the DCE position to connect to DTE equipment.  Use the DTE position 
to connect to DCE equipment. To change the mode, remove the board by 
grasping it and pulling it gently upward. Flip the board around, left to right,  
and reinsert it in the socket so that the correct operating mode, DCE or 
DTE, appears in the upper lefthand corner. 
6. Snap the top cover onto the unit.
Setting 7400B data module hardware options
You configure the 7400B data module using DIP switches on the circuit card 
inside the case
 shows the front and rear of a 7400B data module.
To configure the 7400B data module, proceed as follows.
!
WARNING:
Electrostatic discharge can severely damage sensitive electronic circuits. 
Before handling any electronic hardware, be sure to wear a grounding wrist 
strap or other static-dissipating device. Do not touch exposed circuitry or 
semiconductor chips.
1. If you are not attaching a telephone to the data module, activating data 
metering, or enabling busyout on the local loop, you can use the factory 
default settings. The 7400B data module is already configured for your use. 
Stop now.
POWER
TEST
DATA
METERING
7400B Data Mod ule
AA
CD RD SD
TR
O H
CH ECK
SPEED
DATA
PO RT 2
PO RT 1
PO WER
PHO NE
LINE
7400b RBP 032596
Figure 12.
7400B data module