Avaya 555-233-116 사용자 설명서

다운로드
페이지 246
Connect data modules
Issue 4   October 2002
55
555-233-116
Connecting a single data module
!
CAUTION:
You must install a 105D or 105C isolating data interface adapter when 
connecting data modules to equipment in DC-powered cabinets.
Connect the data module to your house wiring or DEFINITY as follows.
1. Attach a D8W cable to the LINE port of the data module.
2. If you are going to attach a telephone to the data module
a. Attach a 400B2 adapter to the other end of the D8W cable.
b. Plug the adapter into a modular wall jack or 103A connector.
c. Plug a D7AP cord into the 400B2 adapter.
d. Plug the other end of the D7AP cord into the auxiliary power supply 
for the telephone.
You must have a separate power supply for the telephone and for 
the data module.
e. Attach a D8W cable to the PHONE port of the data module.
3. If you are not attaching a telephone, attach the D8W cable from the Line 
port of the data module to a modular wall jack or 103A connector.
4. Attach the data-module power supply to the power connector on the back 
of the data module, and plug the power supply into an AC electrical outlet.
5. Connect an RS-232 cable to the PORT 1 connector on the back of the data 
module. 
6. If the equipment includes a V.35 interface, plug a V.35 cable into the V.35 
connector on the data module.
7. If the data module is a 7400B DCE-only device and if the other end of the 
cable is connected to another DCE device, insert a null-modem adapter 
between the data module and the RS-232 cable.
8. Connect the other end of the RS-232 cable to a serial (COM) port 
connection on the data device (host computer, serial printer, modem, etc.).
9. Go to the configuration procedure for the data module you are using: