Data modules and asynchronous data units
555-233-116
96
Issue 4   October 2002 
Screen 1.
Typical system-configuration listing
2. Locate an unassigned port on a suitable circuit pack, and make a note of 
the corresponding port number.
The port number is the Board NumberUUCSS (where UU is the 2-digit 
cabinet number, C is the single-character carrier identifier, and SS is the 2-
digit slot number) followed by the next 2-digit number, PP, in the sequence 
in the Assigned Ports fields at the right side of the form: UUCSSPP.
For example, in the listing above, the next available port address for the 
TN2181 digital line circuit pack would be 01A0503.
3. From the DEFINITY administration console, open a new data-module form 
by typing
add data-module next 
The system automatically assigns the next available  extension number to  
the data module.