Section 300-Installation
Chapter 4. Trunks and Lines
DBS-2.3/9.2-300
DBS Manual - Revised April 2000
  4-9
Ground Start and DID Trunks
Guidelines
• The following procedure covers ground-start (VB-43531) and DID (VB-
43541) installation using the main trunk connector. For instructions on 
using the expansion trunk connector, see “Trunk and Line Expansion” on 
page 4-44.
• For pinouts and color codes for the main trunk connector, see Table 4-2 on 
• Each circuit on the ground-start trunk card can be used as either a loop-
start or ground-start trunk. By default, all circuits on the ground-start trunk 
are assigned as loop start.
• The ground-start trunk card requires CPC-B Version 1.0 or higher.
• The DID card requires CPC-B (Version 2.0 or higher) and SCC-B 
(Version 1.2 or higher).
• Both ground start and DID trunks require an external -48V floating output 
power supply. The following table shows -48V power consumption for 
one- and two-cabinet systems.
Table 4-4.  -48V current consumption for ground-start and DID trunks
• The following -48V floating output power supplies have been tested with 
DBS ground-start and DID trunks.
Table 4-5.   -48V power supplies tested with the DBS
• The following “Installation” section includes details on installing the -48V 
power supply.
System Size
Current Consumption
(Output voltage = 48
 ±
 4 V
 Ripple voltage = 
±500
  mVp-p)
One-cabinet system
1 Amp
Two-cabinet system
2 Amps
Manufacturer
Model Number
Rating
Valcom
VP-2048B
2 Amps
Tellabs
81-8002
2 Amps