Siemens AG 
6SE7087-6CX86-2BA1 
SIMOVERT MASTERDRIVES AFE 
Operating Instructions 
12-1
 
12 Parameter 
List 
General Visualization Parameters 
to 49 
Analog Input/Output 
from 650 
General Parameters 
from 50 
Interface Configuration 
from 680 
Drive Data 
from 70 
Diagnostic Functions 
from 720 
Hardware Configuration 
from 89 
Gating Unit 
from 760 
Motor Data 
from 100 
Factory Parameters 
from 780 
Control 
from 150 
Special Parameters 
from 800 
Functions 
from 330 
Profile Parameters 
from 900 
Setpoint Channel 
from 410 
Tech Board Parameters 
from 1000 
Control and Status Bit Connections 
from 550 
 
 
 
Key to parameter list 
Example: 
PNU 
 
*:conf-P 
Parameter Name in OP1 
 
Description 
Range  
[Unit] 
Value Texts 
# of Indices 
Factory 
Settings 
read: _/_ 
write: _/_ 
P999 
*1) 
3E7Hex 
"Parameter Name in OP1” 
"Description” 
RDS(2) parameter6) 
Type=I2; 2)  PKW: 1Hex=0.01 Hz; 
PZD Gr.: 03) 
−300.00 to 300.00 
[Hz] 

i001=50.00 
i002=50.00 
or: 
7) 
25)/   BR4) 
25)/   BR4) 
1)  Confirmation parameter: Does not become active until confirmation (press 
P
 key)  
2)  Parameter type 
O2 Unsigned 
16-bit 
value 
I2 
Signed 16-bit value 
L2 Nibble-coded 
quantity 
V2 Bit-coded 
quantity 
3)  Normalization group for PZD 
PZD group 
PZD normalization 
 
0 as PKW normalization 
 
61000Hex = P072 I(n,AFE) 
 
71000Hex = P071 V(n,supply) 
Abbreviations: PZD 
Process Data 
 PKW 
Parameter 
Characteristic 
Value 
4)  Operating states: 
U MLFB 
Input 
(initialization) 
H Hardware 
Configuration 
A Control 
Settings 
B Ready 
(including 
Fault) 
R Run 
5)  Minimum access level which is needed to read or write a parameter. 
Operation via PMU/OP 
2 Standard 
Mode 
 
3 Expert 
Mode 
6)  Abbreviations for indexed parameters 
RDS(2) 
Reserve data set parameter with 2 indices, switched over via control word 2, bit 18 
B/R 
Parameter with switchover option for basic and reserve setting in control word 2, bit 30 
7)  Parameter value is set to a default after initialization. Default settings are determined by the converter MLFB.