Chapter 11:  Board Configuration
144
AltiWare ACM 5.1 Administration Manual
Configuring the MAX Board
The MAX Server is a telecom appliance that consists of an embedded DSP board and two 
access board slots. AltiWare treats the entire MAX system as one board with two access 
board options. The Boards window displays the MAX board as “MAX[xxyy(-T1),xxyy]:
Figure 19. Boards View showing MAX board
xx 
refers to the number of analog trunks, and 
yy
 refers to the number of analog 
extensions. If an access board has a T1/E1 port, 
-T1
 is added to the end.
In the Boards window, double-click the MAX board to open the main Board 
Configuration
 window:
Figure 20. Board Configuration window
The Channel Group Info panel shows the channel groups (groups of channels that 
belong to the same type). For example, if one 4x4xT1 access board and one 4x8 access 
board are installed in the MAX main board, there will be three channel groups for the 
4x4xT1 card, and two channel groups for the 4x8. When one of the channel groups is 
selected, the Channel Mapping List reflects the selection. 
Double-clicking a T1/E1 channel group opens the channel group configuration dialog 
box. For information on configuring in this dialog box, see “T1 and E1 Configuration” 
on page 129. This is ava
ilable on T1 or E1 channel groups only.
In the channel group configuration dialog box, click the Protocol button to open the 
Protocol Configuration dialog box. For information on configuring protocol, see 
“Setting up Channels on the Triton T1/E1 Board” on page 133.
Double-clicking a channel in the Channel Mapping List opens the appropriate 
configuration dialog box for that channel.