AltiGen comm ACM 5.1 사용자 설명서

다운로드
페이지 454
Chapter 12:  Trunk Configuration
AltiWare ACM 5.1 Administration Manual 157
Triton T1/E1 Trunk Properties
To open a configuration dialog box for a Triton T1/E1 channel, do one of the following:
If you’re in the Trunk Configuration window, select a Triton T1/E1 channel from 
the trunk channels list, then click the Trunk Properties button, or just double-click 
the channel in the list.
If you’re in the Trunk View window, right-click the channel and select Channel 
Properties
.
Figure 6. Triton T1 Configuration dialog box
Following are the parameters for the Triton T1 Configuration dialog box:
Parameter
Description
T1 robbed-bit signaling
Protocol
You can set Protocol to one of the following: 
E&M Wink Start (default)
E&M Immediate Start
Ground Start
Loop Start
For signaling from one board to another, only E&M Wink 
Start 
is supported. Loop Start, Ground Start, and E&M 
Immediate Start protocols cannot be used for interfacing 
between two boards.
Dialing Delay 
Specifies the delay, in milliseconds, after trunk seizure and 
before digit dialing. This configuration will slow down the 
system transmitting digits to the CO by a defined delay to 
avoid missing digits. Do not change this value unless advised.
Caller ID and DID Collection