3. Configuration Using the Web Interface
3-5
Configuring SHDSL Ports (8985)
Use the Configuration - SHDSL Port screen to set parameters for a DSL port on 
the 8985 line card.
Procedure
To configure a DSL port:
1. Select a Port from the drop-down list and click on Select. Current values for 
the port are displayed.
2. Enter or select the following fields:
3. Click on Apply.
Field
Description
Line Circuit Name
Enter a name from 1 to 255 characters long to indicate to 
whom the port is assigned. The following values are 
reserved and cannot be used: AVAILABLE (port is not 
assigned), and  FAULTY (port is faulty and can not be 
assigned).
SHDSL Line Profile Name
Enter the name of a DSL line profile to set rates for the 
port.
SHDSL Alarm Profile Name
Enter the name of a DSL alarm profile to set alarm 
thresholds for the port.
Equivalent Working Length
Specify the estimated length of the line. The length is 
used to limit transmit rates according to local spectrum 
management guidelines. 
Port Status
Select Enabled, Disabled, or Reset from the drop-down 
list to determine the status of the port.