Paradyne 8968 사용자 설명서

다운로드
페이지 50
3. Configuration Using the Web Interface
3-12
 
Configuring Cross Connections
Use the Configuration - Cross Connect screen to establish or delete Virtual 
Channel Connections (VCCs) by port or by slot. Connections may be established 
between any combination of:
„
Subtended ports
„
DSL ports
„
Network interface (uplink) 
Default Mappings
A DSL port’s data VPI/VCI is always 0,35. 
Default VC mappings to the SCP card for data service may be determined so:
„
VPI is 2 for ports 1–24 and 3 for ports 25–48
„
VCI is (Slot * 24) + (Port number up to 24) + 7
Port numbers 25 through 48 are reduced (by 24) to 1 through 24, respectively, in 
calculating VCI. So the VCI for Slot 3, Port 1 is the same as the VCI for Slot 3, 
Port 25:
Slot 3, Port 1:   3*24 + 1 + 7 = 80
Slot 3, Port 25:  3*24 + 25 – 24 + 7 = 80
Adding a Port-to-Port Cross Connection
Procedure
To create a cross connection between specified ports:
1. On the Configuration - Cross Connect screen, click on Create New Cross 
Connect. The Configuration - Cross Connect Create screen appears. 
2. Enter or select the following fields:
Field
Description
Port A
Slot
Select from the drop-down list the slot where the card 
associated with this port resides.
Port
Select the port for the cross-connection.
VPI
Enter the VPI for this side of the cross-connection. 
Start VCI
Enter the first VCI for this side of the cross-connection.