EXP1240 System Installation Guide 
 
Revision 06 
© 2013 Uniden America Corp. 
PROPRIETARY AND CONFIDENTIAL  
Page 35 of 71 
∘  The 
IP Status field
 of the base station you are logged into should show 
This 
unit
. Any other base stations in this chain should show 
Connected
 (i.e., 
connected to the network and functioning properly) as their IP status. If any 
base station shows 
Connection Loss
 as its IP status, that base station is not 
connected to the network or has lost power.  
  The primary base station always serves as its own sync source, so the 
DECT 
sync source
 field should display 
Primary:RPN{its own RPN}. 
The 
DECT 
Property
 field shows 
Primary
  This base station's 
DECT sync source
 will show 
(any) RPN
 and its 
DECT 
Property
 field will show 
Locked
.  
∘  Check the 
DECT sync source
 drop-down box for this base station to verify 
that there is a selection for the primary base station with a dBm value. If 
there is not a dBm value, wait for the system to further synchronize 
(approximately 2 minutes). When there is a dBm value, select the primary 
base station from the 
DECT sync source
 drop-down box and click 
Save
∘  If the primary base station is not on the list or if the signal strength is below -
70 to -73 dBm (-74dBm or less), move this base station to a different 
location. (You could also configure the other Level 1 base stations first and 
then come back and configure this one at Level 2.) 
∘  The 
DECT Chain
 appears at the bottom of the display and shows the 
synchronization source for all base stations in this system. Until the primary 
base station is selected as the 
DECT sync source
, there will be a warning in 
the 
DECT Chain
 for this base station. 
Figure 26: 
Base Station Group
 table, synchronization complete (
Multi-cell
 screen) 
   
    
13)  When the system has finished synchronizing, repeat this process for each base station at 
Level 1.