ADJUSTMENTS
MAT SWITCH ADJUSTMENT (IF REQUIRED)
2. Measure the height of the 
threshold plate as shown in FIG. 
42-1B
. If the height is 5/8”, 
go to step 4 (skip step 3). If the 
height is not 5/8”, go to step 3.  
LIFT THRESHOLD
FIG. 42-2A
HEIGHT ADJUSTMENT SCREW 
(RH SIDE SHOWN)
FIG. 42-2B
ADJUSTMENT 
SCREW
LIFT AT GROUND LEVEL
FIG. 42-1A
POWER SWITCH
HEIGHT MEASUREMENT
(RH SIDE SHOWN)
FIG. 42-1B
1. Make sure power switch 
(FIG. 42-1A) is turned 
on. Lower Lift to the 
ground (FIG. 42-
1A)
HEIGHT ADJUSTMENT SCREWS
FIG. 42-3
3. Set edge of the threshold plate to 
5/8” height by turning the adjust-
ment screw on the RH side of 
threshold plate (FIG. 42-2B)
Turn adjustment screw counter-
clockwise (FIG. 42-3) to raise 
threshold plate or clockwise to 
lower. Repeat for LH side of 
threshold plate. Alternately mea-
sure height (see instruction 2). 
Then, turn the adjustment screw 
on RH side and LH side until the 
entire edge of threshold plate is at 
5/8” height.
CCW - RAISE
CW - LOWER
5/8”