46
11921 Slauson 
A
ve.  Santa Fe Springs, CA.  90670  (800) 227-41
16  F
AX (888) 771-7713
1. Position the platform at fl oor level 
(FIG. 46-1).
2. Turn OFF power switch on pump 
cover (FIG. 46-1).
PLATFORM AT FLOOR LEVEL
(LH SIDE SHOWN)
FIG. 46-1
POWER
SWITCH
INBOARD SWITCH ADJUSTMENT (IF REQUIRED)
 NOTE: Do this procedure if the Controller reads “IBRS SW” when Inboard Rollstop is 
locked in the up position. 
 
The adjustment is done correctly if the Controller does not read “IBRS SW” 
when the Inboard Rollstop is locked in the up position.
3. Using the manual backup pump (FIG. 46-
2), lower the platform until inboard rollstop 
(IBRS) is locked in the up position (FIG. 47-
1)
. Refer to Operation Manual for instruc-
tions to operate the manual pump.
USING BACKUP PUMP TO UNFOLD 
(LIFT WITH LH PUMP)
FIG. 46-2
RELEASE
VALVE
BACKUP PUMP 
HANDLE