Polycom 3725-76302-001O 사용자 설명서
Polycom, Inc.
350
See also:
Alert 2601
<cluster>: Cannot reach Lync server <lyncserver> for presence publishing.
The cluster cannot communicate with the specified Lync server at the currently configured Next hop
address. This could indicate a network problem, or a problem with the Lync server.
address. This could indicate a network problem, or a problem with the Lync server.
Click the link to go to the Network > External SIP Peers page to begin troubleshooting. Try to ping the Lync
server’s Next hop address to verify basic connectivity.
server’s Next hop address to verify basic connectivity.
See also:
Alert 2602
<cluster>: Cannot authenticate with <lyncserver> for presence publishing.
The cluster cannot authenticate with the specified Lync server; presence will not be published for Polycom
conference contacts.
conference contacts.
This could indicate incorrect RealPresence DMA system or Lync server configuration.
Click the link to go to the Network > External SIP Peers page to begin troubleshooting. Verify that the Next
hop address, Port, and Transport type settings on this page are correct.
hop address, Port, and Transport type settings on this page are correct.
See also:
Alert 2603
<cluster>: Invalid Lync account URI configured for Lync server <lyncserver>.
The system is unable to authenticate with the Lync server using the currently configured Lync account URI.
Click the link to go to the Network > External SIP Peers page to begin troubleshooting. Try reentering the
Lync account URI for the Lync server in the External SIP Peer configuration area.
Lync account URI for the Lync server in the External SIP Peer configuration area.
See also:
Alert 2604
<cluster>: Cannot reach Lync server <lyncserver> to resolve conference IDs.
The system is unable to connect to the specified Lync server at the currently configured Next hop address.
Attempts to connect to a Lync conference through the RealPresence DMA system will fail.
Attempts to connect to a Lync conference through the RealPresence DMA system will fail.
This could indicate a network problem, or that someone has shut down the Lync server.