TP-141, TP-142 - Overview
 
 
connectors, make sure that the shield of the STP cable is connected to the metal 
casing of the connectors on both ends of the cable. For units which are connected 
via terminal block connectors, the shield of the STP cable must be connected to a 
ground terminal on the units at both ends (use the ground terminal of the power 
supply connection if necessary). 
For a TP cable exceeding a distance of 50m, separate power supplies should be 
connected to the transmitter and to the receiver simultaneously. 
3.2 
Shielded Twisted Pair (STP)/Unshielded Twisted Pair 
(UTP) 
We recommend that you use Shielded Twisted Pair (STP) cable, and stress that 
the compliance to electromagnetic interference was tested using STP cable. There 
are different levels of STP cable available, and we advise you to use the best 
quality STP cable that you can afford.
 
Our non-skew-free cable, Kramer BC-STP 
is intended for analog signals where skewing is not an issue. 
In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-free 
cable, Kramer BC-XTP, may be advantageous, and UTP cable might also be 
preferable for long range applications. In any event when using UTP cable, it is 
advisable to ensure that the cable is installed far away from electric cables, motors 
and so on, which are prone to create electrical interference.