사용자 설명서차례Cisco 7000 and Cisco 7507 ChassisReplacement Instructions1Product Overview2Figure1 Cisco 7000 Chassis Rear View2Figure2 Cisco 7507 Chassis Rear View3Figure3 Power Supply Safety Interlocks4Figure4 Cisco 7000 System Backplane Slot Key Guides4Figure5 Cisco 7507 System Backplane Slot Key Guides5Prerequisites6Safety Guidelines7Lifting the Chassis Safely8Figure6 Lifting Safely8Safety with Electricity9Cable Strain Relief9List of Parts and Tools10Preventing Electrostatic Discharge Damage10Preparing the Work Area11Unpacking the Chassis11Replacing a Rack-Mounted Chassis11Adding a New Chassis to the Rack13Step 1 Follow the instructions in the section “Unpacking the Chassis” on page 11 to unpack the ra...13Step 2 Ensure that there are at least 20 inches of vertical space free in the rack above or below...13Step 3 Follow the instructions in the Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instr...13Step 4 When the replacement chassis is secured in the rack, turn off all power supplies in the ex...13Step 5 Proceed to the section “Moving System Components” on page 18 to move the power supplies an...13Step 6 When all of the components are moved to the new chassis, ensure that all of the captive in...13Step 7 Proceed to the section “Verifying the Installation” on page 24 to verify that all componen...13Step 8 To remove the old chassis (which should now be empty), use a 1/4-inch flat-blade screwdriv...13Step 9 To remove the empty chassis from the rack, position one person in the back of the rack to ...14Step 10 Slowly push the chassis out of the front of the rack while the two assistants in the fron...14Step 11 Follow the safety guidelines in the section “Lifting the Chassis Safely” on page 8, and r...14Replacing the Existing Rack-Mounted Chassis14Step 1 Use the configuration worksheet provided at the end of this document or your own method to...14Step 2 Turn all power supplies OFF.14Step 3 After reviewing the descriptions in the section “Cable Strain Relief” on page 9, disconnec...14Step 4 Remove all power supplies from the existing system and place them aside (leave the process...15Step 5 On the front of the rack, use a 1/4-inch flat-blade screwdriver to loosen and remove the f...16Figure7 Rack Mounting Hardware16Step 6 Position one person in the back of the rack to push the chassis out the front, and positio...17Step 7 Position the removed chassis so that you will have room at the rear of the chassis to remo...17Step 8 Use a Number2 Phillips screwdriver to remove the chassis ears from the removed chassis an...17Step 9 With one person positioned on each side of the replacement chassis, grasp the underside of...17Step 10 Insert the rear of the chassis into the rack and lower it until the bottom of the chassis...17Step 11 Slide the chassis back into the rack until the ears on the chassis are flush against the ...17Step 12 Use the four binder-head screws you removed in Step5 to secure the ears to the front mou...17Step 13 Proceed to the section “Moving System Components” on page 18 to move the power supplies a...17Step 14 When all of the components are moved to the new chassis, reconnect all interface cables t...17Step 15 Proceed to the section “Verifying the Installation” on page 24 to verify that all compone...17Moving System Components18Step 1 Place the existing and replacement chassis side by side, if possible, and ensure that your...18Step 2 Slip on a grounding strap or other ESD-prevention device and attach it to one of the capti...18Step 3 On the existing system, turn all power supply switches OFF (O) if you have not already don...18Step 4 On each interface cable connected to an interface processor, check the available slack to ...18Step 5 Check the slack on cables that are connected to the RP (in the Cisco 7000) or RSP2 (in the...18Step 6 If you must disconnect the cables, label each one and use the configuration worksheet at t...18Moving the Processor Modules18Step 1 Use a screwdriver (Number2 Phillips or 1/4-inch flat-blade) to loosen the captive install...19Figure8 Bottom Ejector Lever and Captive Installation Screw19Step 2 Place your thumbs on the upper and lower ejector levers and simultaneously push the top le...20Step 3 Grasp the carrier handle with one hand and place your other hand under the carrier to supp...20Figure9 Handling a Processor Module During Installation20Step 4 Carefully pull the carrier straight out of the slot, keeping your other hand under the car...20Step 5 Place the back of the carrier in the appropriate slot in the new chassis and align the not...20Step 6 While keeping the carrier at a 90-degree orientation to the backplane, carefully slide the...21Step 7 Using the thumb and forefinger of each hand, simultaneously push the top lever down and th...21Step 8 Use a screwdriver (Number2 Phillips or 1/4-inch flat-blade) to tighten the captive instal...21Step 9 Repeat Steps 1 through 8 for each remaining processor module, working from right to left. ...21Step 10 Proceed to the next section to move the power supplies.21Moving Power Supplies21Step 1 If you have already removed all power supplies, proceed to Step7.21Step 2 Ensure that the switch on each power supply is turned fully to OFF (O), then disconnect al...21Step 3 Disconnect the power cable from each power source.21Step 4 Disconnect the power cable from each power supply.21Step 5 Use a screwdriver to loosen the captive installation screw on the power supply in the lowe...21Step 6 Grasp the power supply handle and pull the supply out of the bay. Place one hand underneat...21Figure10 Handling a Power Supply (AC-Input Power Supply Shown)22Step 7 Fill the lower power supply bay first. Insert the rear of the power supply into the bay an...22Step 8 Push the power supply all the way into the bay. Do not use unnecessary force; firmly push ...22Step 9 Use a screwdriver to tighten the captive installation screw on the top of the power supply.22Step 10 If you are removing or installing a second power supply, use a screwdriver to remove the ...22Step 11 Repeat Steps 2 through 9 for the second power supply, if any.22Step 12 On each power supply in the new chassis, push the cable retention clip down, away from th...22Step 13 To secure the AC-input cable in the power supply AC receptacle, push up the cable retenti...23Step 14 Place the terminal block cover over the terminal block and secure it with the two captive...23Figure11 DC-Input Power Supply Cable Connections23Step 15 Connect the opposite end of each power cable to an appropriate power source.23Step 16 Proceed to the section “Verifying the Installation” on page 24 to apply power and check t...23Verifying the Installation24Checking Connections24Step 1 Check the processor modules to make sure that each is inserted all the way into its slot, ...24Step 2 Check the interface cable connections to the interface processors, and ensure that all cab...24Step 3 Ensure that the console cable is secured to the console port on the RP (in the Cisco 7000)...24Step 4 Check the power supplies for the following:24Restarting the System24Step 1 Turn ON the lower power supply by turning the power supply switch clockwise one-quarter tu...24Step 2 After turning on the lower power supply, turn ON the upper power supply (if one is present...25Step 3 While the system initializes, the boot error LED on the RP (or the CPU halt LED on the RSP...25Step 4 After the system boots the software and initializes the interface processors (approximatel...25Step 5 Verify that all of the enabled LEDs on all interface processors (and on the SP or SSP in t...25Step 6 Verify that the console terminal displays a script and system banner.25Troubleshooting the Installation26LED Descriptions26Power Supply LEDs26Figure12 Power Supply LEDs26Figure13 DC-Input Power Supply LEDs (Similar Location to the AC-Input Power Supply)27System Front Panel LEDs28Figure14 Front Panel LEDs (Cisco 7000 Shown—Identical to Cisco 7507)28Route Processor LEDs (Cisco 7000)29Figure15 RP LEDs29Route Switch Processor LEDs (Cisco 7507)30Figure16 RSP2 LEDs30Interface Processor, SP, and SSP LEDs31System Startup Sequence31Step 1 When you turn the lower power supply ON, the power LED on the lower power supply should go...31Step 2 When you turn the upper power supply ON, the power LED on the upper power supply should go...31Step 3 Listen for the system blower. It generates about 60 dB, so you should immediately hear it ...32Step 4 When you have verified that the power supplies are functioning properly, observe the LEDs ...32Step 5 The CPU halt LED on the RP (or RSP2) should always remain OFF. If it goes on during the st...32Step 6 During the boot process, the LEDs on most of the interfaces go on in irregular sequence; t...32Step 7 When the system boot is complete, the RP (or RSP2) begins to initialize the interface proc...33Step 8 When the system boot is complete, and the SP (on the Cisco 7000) and all interface process...33Figure17 Cisco 7000 Port Configuration Worksheet34Figure18 Cisco 7507 Port Configuration Worksheet35Translated Safety Warnings36Power Disconnection Warning36Power Supply Warning36Power Supply Disconnection Warning37Electric Shock Warning38Chassis Lifting Warning39DC Power Disconnection Warning40Lightning Activity Warning41Chassis Warning—Rack-Mounting and Servicing42Ramp Warning44DC Power Supply Warning44DC Power Supply Wiring Warning45DC Power Connection Warning46Cisco Information Online48크기: 645킬로바이트페이지: 48Language: English매뉴얼 열기