사용자 설명서차례About This Manual5Special Installation Requirements5UL Listed Installations5Basic System5Household Burglary Alarm System Unit (UL 1023)5Household Fire Warning System (UL 985)5UL 1023 & 985 24-Hour Backup5UL 1635 Digital Alarm Communicator System5Central Station Reporting5UL Canada Listed Installations5Canadian Standards CSA Certified Accessories5Residential Burglary Alarm System Unit (ORD-C1023-1974)5Residential Fire Warning System Control Unit (ULC-S545-M89)5California State Fire Marshall Listed Installations6Planning the Installation6Standard Panel6Interrogator 200 Audio Verification Module6Installing the System6System Components6Figure 1. Typical Security System Components6Control Panel6User Interface6Panel Tamper6System Devices7Door/Window Sensor (60-670)7Indoor Motion Sensor (60-639)7Outdoor Motion Sensor (60-639)7Freeze Sensor* (60-742)7Water Sensor* (60-744)7Smoke Sensor (60-848-95)7Carbon Monoxide (CO) Alarm* (60-652-95)7Keychain Touchpad* (60-659)7Remote Handheld Touchpad (60-671)7X-10 Modules*7Interrogator® 200 Audio Verification Module* (60-787)7Planning Sensor Types & Locations7Recommended Sensor Types8Device8Recommended Sensor Type8Device Locations8Control Panel8Remote Handheld Touchpad8Keychain Touchpad8X-10 Modules8House Code and Unit Numbers8To Fill Out the Home Control Planning Table:81. Set the house code on all modules (except the remote siren) to the same letter.82. Set the Remote Siren house code to the next alphabetical letter. For example, if you chose hou...83. Set the module unit numbers.84. List the location of the lamp or appliance in the Location column of the Home Control Planning...85. Write the location of each Lamp Module on an adhesive note and label the module.86. Decide if the device should be activated by sensors, entry/exit delay, time, or a combination....8House Code Assignments9House Codes9Results9Unit #9Result9Installing the System9Materials Needed9Opening the Panel Cover and Chassis9Figure 2. Opening the Panel Cover and Chassis9Mounting the Panel91. Choose a panel location.92. Run all necessary power, phone, siren, and hardwire contact wires to the desired panel location.93. Refer to Figure 3 for mounting hole locations.9Figure 3. Panel Mounting Hole Locations104. For wall mounting, insert anchors into holes where studs are not present.105. Install all screws and tighten gently.10Connecting Hardwire Devices10AC Terminals10HWIN1, HWIN2, and DCOUT Terminals10Sirens10Hardwire Detectors10Wiring Interior Sirens10LD105 Hardwire Interior Siren10Figure 4. Hardwire Interior Siren with Supervision10Wiring Exterior Sirens11Hardwire Exterior Siren with Supervision11Figure 5. Hardwire Exterior Siren with Supervision11Hardwire Exterior Siren without Supervision11Figure 6. Hardwire Exterior Siren without Supervision11Wiring Hardwire Contacts11Figure 7. Connecting Normally Closed Hardwire Reed Switches11Wiring a Phone Line to the Panel11Full Line Seizure11Full Line Seizure Wiring with an RJ-31X121. Run a 4-conductor cable from the TELCO block to the RJ-31X (A in Figure 8).122. Connect the 4-conductor cable wires to the RJ-31X (B in Figure 8).123. Disconnect the Green and Red premises phone jack wires from the TELCO block and splice them to...124. Connect the 4-conductor cable Green and Red wires to the TELCO block TIP (+) and Red to RING (...125. Connect the phone cord included with the panel to the RJ-31X and the panel LINE IN jack (E in ...12Figure 8. Full Line Seizure Wiring with an RJ-31X12Full Line Seizure Wiring with 1 Premises Phone121. Disconnect the phone from the premises phone jack and plug it into the panel PHONE jack (A in ...122. Connect the phone cord included with the panel to the panel LINE IN jack and the premises phon...12Figure 9. Full Line Seizure Wiring with 1 Premises Phone12No Line Seizure12Wiring the Power Transformer13Figure 10. Connecting the Power Transformer13Powering Up the Panel13Installing the Panel Backup Battery131. Position and push the battery between the 2 flexible tabs (A in Figure 11).132. Slide the battery to the left until the tabs snap into place, securing the battery (B in Figur...13Figure 11. Installing the Panel Backup Battery133. Connect the red and black battery leads (included with panel) to the battery and panel termina...13Figure 12. Connecting the Battery Leads to the Battery and Panel Terminals13Applying AC Power131. Remove the center screw from the outlet cover plate and hold the cover plate in place.132. Plug the transformer into the lower receptacle of the outlet so that the hole in the transform...133. Insert the cover plate screw through the transformer tab and the outlet cover plate. Tighten t...13Installing X-10 Modules13Lamp and Appliance Modules131. Set the unit code dial to a unit number different from all other X-10 modules (between 1 and 8).132. Set the house code for the installation.143. Plug the module into a wall outlet.144. Plug the lamp/appliance into the module.14Universal Module141. Set the unit code dial to a unit number different from all other X-10 modules (between 1 and 8).142. Set the house code for the installation.143. Set the module switches to momentary and relay only.144. Connect the module terminals to the desired device terminals.145. Plug the universal module into a wall outlet.14Sensor Installation14Programming14Entering Program Mode14Utility Access Code 1 (Dealer Code)14Utility Access Code 2 (Installer Code)141. Open the panel cover.142. Enter Utility Access Code 1 or 2 using the numbered keys.14Program the panel in this order:141. Set the panel clock.142. Add (learn) sensors.143. Set House Code and Light & Appliance Controls (Entry/Exit activated lights, Sensor activated l...144. Change numbered Options as needed.14Exiting Program Mode14Reset Memory to the Factory Defaults141. Open the panel cover and enter Utility Access code 1.142. Unplug the transformer and disconnect the battery.143. Simultaneously press and hold Cancel, Clock Set, and Minutes +.144. Restore power to the panel with either the battery or the transformer while pressing these thr...145. Connect the remaining power source to the panel.14Set the Clock141. Press Clock Set from the Start Menu.142. Press the Hours + and – keys and listen to the voice prompts. Stop when panel voice announces ...143. Press the Minutes + and – keys and listen to the voice prompts. Stop when the panel announces ...144. Press Done. The panel announces the set time.14Adding (Learning) Sensors14Device Programming15Device15To Program151. Press Add. The panel announces “Select from Main Menu.”152. Press Sensor/Remote. The panel announces “Press button on sensor.”153. Press the sensor program button or release sensor tamper switch. The panel announces “Keychain...154. Press Sensor/Remote repeatedly until you hear the name or item you want to use. An alphabetica...155. Press DONE when you hear the desired name. The panel announces “Use numbered keys to enter sen...156. Enter the 2-digit sensor group. The panel announces the sensor group and the first available s...157. Press DONE. The panel confirms programming by announcing the sensor number, name, and group.15Deleting Sensors161. Press Delete. The panel announces “Select from Main Menu.”162. Press Sensor/Remote repeatedly until you hear the name and number you want deleted, then press...16X-10 Module Operation161. Press Add.162. Press Light Control repeatedly until you hear the desired house code letter.163. Press DONE.164. Set the HOUSE dial on each lamp, appliance, and universal module, to the same letter.165. Set the HOUSE dial on powerhorn/remote sirens to the next sequential alphabetical letter.161. Press Add.162. Press Light Control.163. Press Unit # repeatedly until you hear the unit number that matches the one you chose for the ...164. Press Entry/Exit Delay. The panel confirms your programming.161. Press Add.162. Press Light Control.163. Press Unit # repeatedly until you hear the unit number that matches the one you chose for the ...164. Press Sensors until you hear the sensor you want to control the light.165. Press DONE. The panel confirms your programming.161. Press Add.162. Press Light Control.163. Press Unit # until you hear the unit number that matches the one you chose on the module.164. Press Time.165. Press Hours and Minutes to set the beginning of the schedule.166. Press DONE.167. Press Hours and Minutes to set the end of the schedule.168. Press DONE. The panel confirms your programming.161. Press Delete.162. Press Light Control.163. Press Unit # repeatedly until you hear the unit number you want deleted.164. Press Entry/Exit Delay, then press DONE. The panel confirms your programming.161. Press Delete.162. Press Light Control.163. Press Unit # repeatedly until you hear the unit number you want deleted.164. Press Sensors until you hear the one you want deleted.165. Press DONE. The panel confirms your programming.161. Press Delete.162. Press Light Control.163. Press Unit # repeatedly until you hear the unit number you want deleted.164. Press DONE. The panel confirms your programming16Numbered Options16Option 01: Panel Piezo Beeps (Default = On)17Panel Piezo Beeps17Activity17Piezo Beep Response17To turn on Panel Piezo Beeps, press:17To turn off Panel Piezo Beeps, press:17Option 02: Panel Voice (Default = On)17To turn on Panel Voice, press:17To turn off Panel Voice, press:17Option 03: Latchkey (Default = Off)17To set Latchkey, press:17To turn off Latchkey, press:17Option 04: Primary Phone Number (Default = none)17To set Primary Phone Number, press:17To delete Primary Phone Number, press:17Option 05: Secondary Phone Number (Default = none)17To set Secondary Phone Number, press:18To delete Secondary Phone Number, press:18Option 06: Downloader Phone Number (Default = none)18To set Downloader Phone Number, press:18To delete Downloader Phone Number, press:18Option 07: Account Number (Default = 00000)18To set Account Number, press:18To delete Account Number, press:18Option 08: Phone Lock (Default = off)18To turn on Phone Lock, press:18To turn off Phone Lock, press:18Option 09: Downloader Code (Default = 12345)18To set Downloader Code, press:18To delete Downloader Code (return to default), press:18Option 10: Entry Delay (Default = 030 sec)18To set Entry Delay, press:18To reset Entry Delay (return to default), press:18Option 11: Exit Delay (Default = 060 sec)18To set Exit Delay, press:19To reset Exit Delay (return to default), press:19Option 12: Phone Mod 1 (Default = 0)19Phone Mod 119Setting #19Content19Format19To set Phone Mod 1, press:19To reset Phone Mod 1 (return to default), press:19Option 13: Phone Mod 2 (Default = 00)19Phone Mod 219Setting #19Content19Format19To set Phone Mod 2, press:19To reset Phone Mod 2 (return to default), press:19Option 14: DTMF Dialing (Default = on)19To turn on DTMF Dialing, press:19To turn off DTMF Dialing, press:19Option 15: No Activity Time-out (Default = off)19To set No Activity Time-out, press:20To turn off No Activity Time-out, press:20Option 16: Auto Phone Test (Default = off)20To set Auto Phone Test, press:20To turn off Auto Phone Test, press:20Option 17: Dialer Delay (Default = off)20To set Dialer Delay, press:20To turn off Dialer Delay, press:20Option 18: Alarm Cancel Report (Default = 005 minutes)20To turn on Alarm Cancel Report, press:20To turn off Alarm Cancel Report, press:20Option 19: RF Timeout (Default = 12 hours)20To change RF Timeout, press:20To reset RF Timeout (return to default), press:20Option 20: Manual Phone Test (Default = on)20To turn on Manual Phone Test, press:20To turn off Manual Phone Test, press:20Option 21: Opening Reports (Default = off)21To turn on Opening Reports, press:21To turn off Opening Reports, press:21Option 22: Closing Reports (Default = off)21To turn on Closing Reports, press:21To turn off Closing Reports, press:21Option 23: Force Armed Report (Default = off)21To turn on Force Armed Report, press:21To turn off Force Armed Report, press:21Option 24: AC Power Failure Report (Default = off)21To turn on AC Power Failure Report, press:21To turn off AC Power Failure Report, press:21Option 25: CPU Low Battery Report (Default = on)21To turn on CPU Low Battery Report, press:21To turn off CPU Low Battery Report, press:21Option 26: Fail to Communicate (Default = on)21To turn on Fail to Communicate, press:21To turn off Fail to Communicate, press:21Option 27: Ring/Hang/Ring (Default = 1)21Ring/Hang/Ring Settings21Setting21Control Panel answers after:211. Call the panel location.212. Let the phone ring once, then hang up.213. Wait at least 10 seconds but not more than 40, then call the panel location again. The panel s...22To turn on Ring/Hang/Ring, press:22To turn off Ring/Hang/Ring (disable remote access), press:22Option 28: No Delay from Keychain Touchpad (Default = off)22To turn on No Delay from Keychain Touchpad, press:22To turn off No Delay from Keychain Touchpad, press:22Option 29: Panel Piezo Alarms (Default = on)22To turn on Panel Piezo Alarms, press:22To turn off Panel Piezo Alarms, press:22Option 30: Panel Panic Alarms (Default = on)22To turn on Panel Panic Alarms, press:22To turn off Panel Panic Alarms, press:22Option 31: Downloader Enable (Default = on)22To turn on Downloader Enable, press:22To turn off Downloader Enable, press:22Option 32: 300 Baud (Default = on)22To turn on 300 Baud, press:22To turn off 300 Baud, press:22Option 33: Audio Verification (Default = off)22To turn on Audio Verification, press:22To turn off Audio Verification, press:22Option 34: Fail to Open Report (Default = off)22To turn on Fail to Open Report, press:22To turn off Fail to Open Report, press:22Option 35: Fail to Close Report (Default = off)23To turn on Fail to Close Report, press:23To turn off Fail to Close Report, press:23Option 36: Sensor Activated Light Lockout Start Time (Default = off)23To set Sensor Activated Light Lockout Start Time, press:23To turn off Sensor Activated Light Lockout Start Time, press:23Option 37: Sensor Activated Light Lockout Stop Time (Default = off)23To set Sensor Activated Light Lockout Stop Time, press:23To turn off Sensor Activated Light Lockout Stop Time, press:23Option 38: Auto Arm (Default = off)23To turn on Auto Arm, press:23To turn off Auto Arm, press:23Option 39: Siren Timeout (Default = 4 min.)23To set Siren Timeout, press:23To turn off Siren Timeout, press:23Option 40: Trouble Beeps (Default = on)24To turn on Trouble Beeps, press:24To turn off Trouble Beeps, press:24Option 41: Chime Voice (Default = off)24To turn on Chime Voice, press:24To turn off Chime Voice, press:24Option 42: Speaker Level (Default = 8)24To set Speaker Level, press:24To turn off Speaker Level (return to default), press:24Option 43: Numeric Pager/Voice Event Notification Phone Number (Default = off)24To set Numeric Pager/Voice Event Notification Phone Number, press:24To delete Numeric Pager/Voice Event Notification Phone Number, press:24Option 44: Numeric Pager/Voice Event Notification Phone Mod 3 (Default = 09)24Phone Mod 324Setting #24Content24Format24To set Numeric Pager/Voice Event Notification Phone Mod 3, press:24To reset Numeric Pager/Voice Event Notification Phone Mod 3 (return to default), press:24Option 45: Sensor Alarm Restoral Report (Default = off)25Sensor Alarm Restoral Settings25Setting25When Restorals are Reported25To turn on Sensor Alarm Restoral Report, press:25To turn off Sensor Alarm Restoral Report, press:25Option 46: Fire Shutdown - AVM (Default = off)25To turn on Fire Shutdown - AVM, press:25To turn off Fire Shutdown - AVM, press:25Option 47: AVM Mode (Default = off)25To set AVM Mode to Callback, press:25To set AVM Mode to Instant, press:25Option 48: Panic Talk - AVM (Default = off)25To turn on Panic Talk - AVM, press:25To turn off Panic Talk - AVM, press:25Option 49: Arming LEDs Shutdown (Default = off)25To turn on Arming LEDs Shutdown, press:25To turn off Arming LEDs Shutdown, press:25Option 50: RF Jam Detect (Default = off)25To turn on Arming LEDs Shutdown, press:25To turn off Arming LEDs Shutdown, press:25Option 51: 24 Hour Sensor Tamper (Default = off)25To turn on 24 Hour Tamper, press:26To turn off 24 Hour Tamper, press:26Option 52: Unvacated Premises (Default = on)26To turn on Unvacated Premises, press:26To turn off Unvacated Premises, press:26Option 53: Hardwire Siren Supervision (Default = off)26To turn on Hardwire Siren Supervision, press:26To turn off Hardwire Siren Supervision, press:26Option 54: Access Code Length (Default = 4)26Access Code Length Defaults26Setting26Default Code26To change Access Code Length, press:26To reset Access Code Length (to default), press:26Option 55: Status Beep Volume (Default = 07)26To set Status Beep Volume, press:26To reset Status Beep Volume (return to default), press:26Option 56: Call Waiting (Default = off)26To program Call Waiting, press:27To delete Call Waiting, press:27Option 57: Supervisory/Tamper Report (Default = off)27To report supervisories as Tamper Reports, press:27To report supervisories as Supervisory Reports, press:27Option 58: Remote Touchpad Arming (Default = off)27To turn on Remote Touchpad Arming, press:27To turn off Remote Touchpad Arming, press:27Option 59: Exit Extension (Default = on)27To turn on Exit Extension, press:27To turn off Exit Extension, press:27Option 60: Secure Arming (Default = off)27To turn on Secure Arming, press:27To turn off Secure Arming, press:27Option 61: Demo Mode (Default = off)27To turn on Demo Mode, press:27To turn off Demo Mode, press:27Option 62: Supervisory Protest (Default = off)27To turn on Supervisory Protest, press:27To turn off Supervisory Protest, press:27Option 63: 24 Hour Time (Default = off)27To turn on 24 Hour Time, press:27To turn off 24 Hour Time, press:27Option 64: No Arm on Panel Low Battery (Default = off)28To turn on No Arm on Panel Low Battery, press:28To turn off No Arm on Panel Low Battery, press:28Option 65: No Usage Report (Default = off)28To turn on No Usage Report, press:28To turn off No Usage Report, press:28Option 66: External Siren Delay (Default = off)28To turn on External Siren Delay, press:28To turn off External Siren Delay, press:28Option 67: Quick Exit (Default = off)28To turn on Quick Exit, press:28To turn off Quick Exit, press:28Option 68: Swinger Shutdown (Default = on)28To turn on Swinger Shutdown, press:28To turn off Swinger Shutdown, press:28Option 69: SIA Limits (Default = on)*28SIA Limits28Affected Option28SIA Limits (Option 69 on)28Factory Ranges (Option 69 off)28To turn on SIA Limits, press:28To turn off SIA Limits, press:28Option 70: Not Available29Option 71: Programming Report (Default = off)29To turn on Programming Report, press:29To turn off Programming Report, press:29Option 72: Supervisory Time (Default = 12:00am)29To set Supervisory Time, press:29To turn off (disable) Supervisory Time, press:29Option 73: Modem Sensitivity (Default = off)29To turn on Modem Sensitivity, press:29To turn off Modem Sensitivity, press:29Option 74: Silent Panel Police Panic (Default = off)29To turn on Silent Panel Police Panic, press:29To turn off Silent Panel Police Panic, press:29Option 75: VOX Mic Gain (Default = 14)29To set VOX Mic Gain, press:29To reset Vox Mic Gain (return to default), press:29Option 76: VOX Gain Range (Default = 64)29To set VOX Gain Range, press:29To reset VOX Gain Range (return to default), press:29Option 77: Manual Mic Gain (Default = 64)29To set Manual Mic Gain, press:29To reset Manual Mic Gain (return to default), press:29Option 78: VOX Receiver Gain (Default = 6)30To set VOX Receiver Gain, press:30To reset VOX Receiver Gain (return to default), press:30Option 79: Panel Cover Tamper (Default = off)30To turn on Panel Cover Tamper, press:30To turn off Panel Cover Tamper (return to default), press:30Option 80: Alarm Report Verification (Default = off)30To turn on Alarm Report Verification, press:30To turn off Alarm Report Verification (return to default), press:30Programming System Access Codes30Master Access Code30Access Codes (1 - 5)30Panic Code301. Press Add.302. Press Access Code button. Continue pressing this button until you hear the access code to be c...303. Press DONE.304. Enter the new access code by using the numbered keys. The panel announces the new code.301. Press Delete.302. Press Access Code. Continue pressing this button until you hear the access code to be deleted.303. Press DONE. The panel announces the code is deleted.30Testing the System30Control Panel30Arming Levels31Arming Level31Description of Level31Sensors311. Place all sensors in their secured (non-alarm) state.312. Open the panel cover.313. Enter the appropriate access code.314. Press Test.315. Press DONE.31Sensor Tripping Instructions31Sensor31Do This316. Interior sirens and speakers sound transmission beeps and a voice announcement identifies the ...31Minimum Beeps32Type of Sensor32Number of Beeps327. Press DONE. The panel announces, Sensor Test OK.328. If Cancel or DONE is pressed and the panel has not heard from all sensors, the panel will resp...32Improving Sensor/Panel Communication32Antenna32If a Sensor Fails the Sensor Test32To reposition a sensor321. Rotate the sensor and test for improved sensor communication at 90 and 180 degrees from the or...322. If poor communication persists, relocate the sensor.32To relocate a sensor321. Test the sensor a few inches from the original position.322. Increase the distance from the original position and retest until an acceptable location is fo...323. Mount the sensor in the new location.324. If no location is acceptable, replace the sensor.32To replace a sensor321. Test a known good sensor at the same location.322. If the transmission beeps remain below the minimum level, avoid mounting a sensor at that loca...323. If the known-good sensor functions, contact ITI for repair or replacement of the problem sensor.32Phone Communication32To perform a phone test or Downloader (DL) phone test321. Open the panel cover.322. Enter the appropriate access code.323. Press Test twice to perform a phone test324. Press DONE. The panel confirms that a phone test or downloader phone test has begun. When the ...32If the phone test fails321. Check that the panel is connected to the phone jack.322. Check the phone number programmed into the panel.323. Perform the phone test again.324. If the phone test fails again, check the phone connection wiring.32Off-Site Phone Operation33Remote Phone Operation33System Function33Phone Command33Central Station Communication33To test communication with the central station:331. Call the central station and tell the operator that you will be testing the system.332. Arm the system.333. Test each of the wireless panic buttons and trip at least one sensor of each type (fire, intru...334. When you finish testing the system, call the central station to verify that the alarms were re...33User Codes for Opening and Closing Reports33Arm or Disarm from:33Reports as User:33Pager Communication33Pager Reporting Message33Reports33Numeric Message332-Way Voice Operation331. After the panel has completed reporting the alarm, pick up the CS phone and press the Ç button...332. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.333. Press 99 to terminate the session.33Audio Verification Set34Phone Button(s)34Function34Voice Event Notification341. Contact the central monitoring station (if system is monitored) to inform them you are testing...342. At the system site, put the system into an alarm condition.343. At the calling location, pick up the phone after it starts ringing. You should hear the panel ...344. Press Ç and the panel voice identifies the alarm. If there is more than one alarm in progress,...345. After listening to the alarm information, press É to terminate the call.34X-10 Operation34Manual Lamp Module Control34X-10 Siren and Lamp Module Functions341. Fire (highest priority)342. Intrusion343. Emergency34Alarm Siren and X-10 Light Information34Fire34Intrusion34Emergency34Emergency Planning35Emergency Planning Floor Plan35Figure 13. Diagram of smoke detector locations.35Appendix A: Troubleshooting36System Status36Control Panel36Options (Programmable by the homeowner)36Sensors36X-10 Modules36Appendix B: System Configuration37Sensor Assignments/Locations37Sensor No.37Device37Sensor Group37Sensor Name/Location37Notes37Alphabetical Listing of Sensor Names37Sensor Group Characteristics38Type38Name/Application38Siren Type38Delay38Restoral38Supervisory38Active in Levels38Delays:38Home Control Planning Table*39Module39Activated by39Time Activated39Unit #39Type39Location39Sensor39Entry/Exit39Start Time39Stop Time39System Access Codes39System Access Codes39Type39Default39Installer Settings39Option Settings39Opt. #40Function40Default40Delete40Range40Who Can Change:40Installer Settings40Specifications43크기: 1.36메가바이트페이지: 44Language: English매뉴얼 열기