사용자 설명서차례Top1Reference Guide1Contents3General Information9Safety Summary9Symbols11Propaq Encore Documentation13The Documentation Set13About This Reference Guide13Statement of Expectations of the Reader13Getting Started15Introducing the Propaq Encore15Intended Use15Propaq Encore Models and Options15Expansion Module16Propaq Encore Pulse Oximetry Option (SpO2)16Capnography (CO2) Options16Impedance Pneumography (RESP) Option17Printer Option17Propaq-to-Acuity Option17Modem-Propaq Option17HP-compatible Side Panel Option17Using the Propaq Encore18System Controls (Right Side Panel)18On/Off Switch18Input Fuse18Power Input Connector18Defib Sync Connector19Real-Time ECG Output Connector19Battery Charging Light19Connector for Acuity or Modem-Propaq19Alarm Lights19ALARM Light19ALARM(S) OFF Light19Power-up Screen20Powerup Equipment Alert: Program Fault, Settings Lost21Patient Connections22Option Connectors23Propaq Encore Display24Propaq Encore Buttons25Propaq Encore Menus26Key-press Route to Setup Menu 127Key-press Route to Setup Menu 228Monitor Setup29Selecting Waveforms for Display31Display Priorities31Setting the Time and Date31Time/Day Settings and Trends32Changing the Date Format, Filter, and Units32Setting the Current, Custom, and Powerup Modes33Printer Functions35PRINTER FAULT Messages36Learning the Propaq Encore37Using In-Service Mode37What You Can Do With In-Service Mode37NIBP38Printer Message38What You Cannot Do With In-Service Mode38Patient Monitoring39ECG/RESP39Intended Use-Impedance Pneumography (RESP)39Intended Use-ECG40ECG Connector and Applicable Accessories41Preparation42Preparing the Monitor42Preparing the Patient42Setting Up the ECG/RESP Channel44Setting ECG/RESP Alarms44How ECG/RESP is Displayed45Patient Artifact45ECG/RESP Menus and Status Window45Impedance Pneumography Selections45Impedance Pneumography Selections46Using the Propaq Encore With Pacemaker Patients47Pacemaker Signals47Pacer Display47Turn On and Off the Pacemaker Indicator47Noise on the signal48Using the Filter to Better Display a Waveform48ECG Messages48RESP Messages49Invasive Pressure50Intended Use50Invasive Pressure Connectors and Transducers50Preparation51Preparing the Transducer51Zeroing the Transducer51Setting up the Pressure Channel52Setting the Invasive Pressure Alarms52Rezeroing a Transducer52How Invasive Pressure is Displayed53Invasive Pressure Messages54NIBP56Intended Use56Improve NIBP Accuracy with Smartcuf™57NIBP Connector and Cuffs58Preparation59Place and Connect the Cuff59Set Up the NIBP Channel60Set the NIBP Alarm Limits62NIBP Display Default Settings62Important Information About Automatic Measurements62NIBP Messages62NIBP IN PROGRESS Message65Temperature66Intended Use66Temperature Connectors and Probes66Preparation66How Temperature is Displayed66Temperature Messages67Pulse Oximetry (SpO2)68Perform SpO2 Monitoring with Masimo Option69Perform SpO2 Monitoring with Nellcor Option70Perform SpO2 “Spot-Check” Monitoring73SpO2 Messages73Capnography (CO2)75Intended Use75Mainstream CO2 Option76Sidestream CO2 Option76CO2 Measurements and Display76Breath Rate Measurements77Apnea Events77Numeric Area Status Messages77CO2 Display Menus and Status Window78Mainstream CO2 Menu and Status Window78Sidestream CO2 Menu and Status Window79Mainstream CO2 Monitoring80How to Set Up the CO2 Channel and Alarm Limits81Sidestream CO2 Monitoring83Connect the Watertrap84Set Up the CO2 Channel and Alarm Limits84Connect to a Non-Intubated Patient85Connect to an Intubated Patient86CO2 Messages86Mainstream CO2 Messages86Sidestream CO2 Messages88Alarms and Limits91Alarms Window and Menu91Alarm Status Window91Alarms Menu91Adjusting the Alarm Tone Volume91Types of Propaq Alarms93Patient Alarms: Definitions and Indications93Life-Threatening Alarms94Temporary Alarms94Responding to Patient Alarms95Suspend an Alarm Tone95Turn Off or Change Alarm Limits95Responding to Life-Threatening Alarms96Alarm Prints96Alarm Holdoffs97Propaq Audio and Visual Alarm Holdoffs97Propaq Audio Alarm Holdoff with Acuity97Setting Alarm Limits98Adjust Limits with STAT SET98Turning On and Off All Limits99Changing Individual Limits99Customizing Propaq Encore Alarm Limits100Equipment Alerts101Definitions and Indications101Responding to Equipment Alerts101Power-up Equipment Alert: Program Fault, Settings Lost102Trends103The Trend Status Window and Menu103How Trends are Accumulated104NIBP Trends104Displaying Trends104Selecting a Trend (NXT TRND)105Printing107Printing Patient Data107Printing Waveforms107The ECG Waveform107The Invasive-pressure Waveforms107The SpO2 Plethysmograph107CO2 and RESP Waveforms108Printing NIBP Measurements109Printing the Apnea Ticket110Printing When a Patient Alarm Occurs111OxyCRG112OxyCRG on Alarm112Printing Trends113Printing a Single Trend113Printing Several Trends113Automatic Trend Prints114Acuity Central Monitoring System115Intended Use115Connecting to the Acuity System115Key-press Route to Acuity Menu117Press NET OFF to Disconnect from Acuity117Printing at Acuity118Network Alert Message118Power Sources119Power Adapter Intended Use119Verifying Proper Power Adapter Configuration120Power Adapter Configurations120Replacing the Power Adapter Fuses120Procedure121Battery Care123Recharging Time123Monitor Functions Resumed123Operating Times Using Battery Power123Monitor Functions Based on Battery Voltage124Checking Battery Voltage124Replacing the Fuse124Care and Maintenance125Inspect and Clean the Monitor and Accessories125Maintenance126Service Interval Recommendations126Product Recycling127Monitor Care127Environmental Operating and Storage Limits127Extended Storage Precautions127Battery Removal127Printer Paper Removal128Printer Maintenance128Loading Paper128Customer Services130Ordering and Customer Service130Technical Service130Repacking130Defibrillator Synchronization131Defib Sync Connector and Cables131Installing the Defib Sync Interface to the LIFEPAK 5131Removing the Defib Sync Interface from the LIFEPAK 5132Synchronized Cardioversion Using the LIFEPAK 5133Synchronized Cardioversion Using the LIFEPAK 6s134Defib Sync Message136Specifications137ECG137Real-Time ECG Analog/Defib Sync139Impedance Pneumography (RESP)140Invasive Pressure141NIBP142Temperature143Pulse Oximetry (SpO2)144Capnography (CO2)146Alarms150Trends151Display151Monitor (Environmental)152Monitor (Physical)153Printer154Power155Power Adapters156Factory Default Settings158In-Service Simulated Values160Glossary161Index171크기: 2.2메가바이트페이지: 178Language: English매뉴얼 열기