Background 
Newer models of the Tracer 3202 outdoor unit will have 1.5 to 2 meters of twisted pair cable 
(“pigtail”) preattached to the 3202 base.  The twisted pair conductors are pre-stripped and ready 
for crimping and attachment to a receptacle connector.  A receptacle connector kit is available 
that will mate to existing customer-end cable connectors used with the original 3202 model.  The 
contents of this kit include: 
• 
1 CPC (circular plastic connector) receptacle 
• 
1 CPC strain relief 
• 
4 receptacle crimping pins (male gender) 
The instructions described in this document refer to the 3202 pre-attached cable only.  For 
instructions on attaching the plug connector to the customer cable, please consult the Tracer 
2210/3202 System Manual (provided on the Tracer 2210/3202 Documentation CD).  
 
Directions 
Figure 1 shows a detailed view of the connector assembly required to attach the receptacle 
connector to the pre-attached 3202 cable.  The plug connector assembly is shown for reference 
only. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1 – Connector Assembly Diagram 
 
The provided 3202 pigtail cable has heat shrink tubing on conductor pairs 1 and 2.  Insert the 1,2 
pair in the 1,2 slots in the receptacle, without regard to which conductor is wired to conductor 1 
or conductor 2.  Likewise, insert the 3,4 pair in the 3,4 slots in the receptacle, without regard to 
which conductor is wired to conductor 3 or conductor 4. 
 
2 3 
Detail B – B 
Detail A – A
A
A
1
2
3
4
1
2
3
4
P1 P2 
Schematic 
P1 
P2 
x 2 
B
B
2 3 
Plug Connector 
(Customer end) 
Receptacle Connector with Strain Relief 
(3202 end)
3202 Pigtail Cable 
Customer Cable