Primary alkaline button cell 
(series V
...
 
1. 
Identification of the product and of the company undertaking 
Product details 
Trade name: 
Primary alkaline button cell 
Voltage: 
1,5 V (or multiples of this in case of multi-cell configurations) 
Electrochemical system: 
Zinc/mercury | NaOH/KOH electrolyte | manganese dioxide 
Anode (negative electrode): 
Zinc/mercury 
Cathode (positive electrode): 
Manganese dioxide 
 
Supplier details 
Address: 
VARTA Microbattery GmbH 
Daimlerstr. 1 
D-73479 Ellwangen/Jagst 
Germany 
Emergency telephone number: 
+49-7961-921-110 
 
Legal Remark (U.S.A.) 
Material Safety Data Sheets (MSDS) are a sub-requirement of the Occupational Safety and Health Administration 
(OSHA) Hazard Communication Standard, 29 CFR Subpart 1910.1200. This Hazard Communication Standard does 
not apply to various subcategories including anything defined by OSHA as an "article". OSHA has defined "article" as 
a manufactured item other than a fluid or particle; (i) which is formed to a specific shape or design during 
manufacture; (ii) which has end use function(s) dependent in whole or in part upon its shape or design during end 
use; and (iii) which under normal conditions of use does not release more than very small quantities, e.g. minute or 
trace amounts of a hazardous chemical, and does not pose a physical hazard or health risk to employees. 
Because all of our batteries are defined as "articles", they are exempted from the requirements of the Hazard 
Communication Standard. 
Legal remark (EU) 
These batteries are no “substances” or “preparations” according to Regulation (EC) No 1907/2006 EC. Instead they 
have to be regarded as “articles”, no substances are intended to be released during handling. Therefore there is no 
obligation to supply a MSDS according to Regulation (EC) 1907/2006, Article 31. 
General remark 
This “Safety Information” is provided as a service to our customers. The details presented are in accordance with our 
present knowledge and experiences. They are no contractual assurances of product attributes. 
2. 
Hazards identification 
A sealed zinc/manganese dioxide button cell is not hazardous in normal use (as defined in chapter 7). 
In case of mistreatment (prolonged deep discharge, charge, reverse charge, external short circuit…) and in case of 
fault, some electrolyte can leak from the cell. In these cases refer to the risk of potassium hydroxide solution or 
sodium hydroxide solution (corrosive, pH > 14). Charging may cause rupture. The electrode materials are only 
hazardous, if the materials are released by mechanical damaging of the cell or if exposed to fire.