Peerless Industries SA771PU Manual Do Utilizador

Página de 70
7 of 70
ISSUED: 10-30-09   SHEET #: 095-9299-11  03-22-12
Installation to Solid Concrete or Cinder Block
Determine and mark the desired display center on the 
wall. Place wall plate template (wall arm) on wall with 
top mounting slots 9" (229 mm) above desired display 
center as shown in fi gure 2.1 on page 6. Level wall 
plate template (wall arm) on wall and mark center of 
four mounting holes making sure that the mounting 
holes. Drill four 3/8" (10 mm) dia. pilot holes to a depth 
of 3" (76 mm). Insert anchors (D) into holes fl ush with 
wall as shown (right). Place wall arm over anchors and 
secure with 5/16 x 3" screws (C). Level, then tighten all 
fasteners.
D
2
2
A
fi g.  2.3
C
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual 
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM 
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a 
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING
•  Tighten screws so that wall plate is fi rmly attached, 
but do not overtighten. Overtightening can damage 
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly 
to load-bearing concrete.
•  Never attach concrete expansion anchors to 
concrete covered with plaster, drywall, or other 
fi nishing material. If mounting to concrete surfaces 
covered with a fi nishing surface is unavoidable (not 
evaluated by UL), the fi nishing surface must be 
counterbored as shown below. Be sure concrete 
anchors do not pull away from concrete when 
tightening screws. If plaster/drywall is thicker than 
5/8" (16 mm), custom fasteners must be supplied 
by installer (not evaluated by UL).
WARNING
SOLID CONCRETE
CINDER BLOCK
CUT
A
W
A
Y
 VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
1
3
2
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
A
D
C
concrete
surface