Niles Audio IR-KIT Manual Do Utilizador

Página de 20
7
Power Status
You can send a Power Status signal to IR-SMR
receiver by connecting a 12V DC power supply from
the switched AC power outlet of the preamp/receiver
to the status input jack of your IR-CB2. Any 12V DC
power supply with a minimum of 100mA current
capacity can be used.
Hi/Low Emitter Output Switches
Emitter Output positions 4 and 5 have Hi/Low output
options. Set these switches to the appropriate
position depending on what
JobSite Emitter you intend to
use. When you are using an
IR-E1 or IR- E2 Emitter, set the
switch in the LOW position. If
you are using a JobSite 
IR-E1HO Emitter, set the
switch in the HI position.
Note: Using an IR-E1 or IR-E2 Emitter with the
Emitter Output Switch set to the HI position, can
damage the emitter.
12-Volt Trigger  Output
The JobSite IR-CB2 provides a 12V
DC output that can be triggered
one of two ways:
1. The presence of status voltage
on the 12V DC status input jack.
2. Discrete infrared On and Off
commands.
This output can be used to trigger any device that
requires 12V DC to be activated. 
Note: Status voltage takes priority over IR command.
Figure 2
3-30V
AC/DC
STATUS
IN
Figure 3