VIZIO VS-900 Manual Do Utilizador
![VIZIO](https://files.manualsbrain.com/attachments/afcb7ebda03ef1dc12794427b874774354715abf/common/fit/150/50/be5c55fefca07e130b7d08f722cd76da334e0470d2a07ac122d5a5816ded/brand_logo.jpeg)
TOA VS-900 Programmer’s Guide
5
Communication Specifications
Transmission System: Half-duplex
Baud Rate: 19,200 Bps
Transmission Format: <1 Start Bit> <8 Data bits> <1 Even Parity Bit> <1 Stop Bit>
Baud Rate: 19,200 Bps
Transmission Format: <1 Start Bit> <8 Data bits> <1 Even Parity Bit> <1 Stop Bit>
Message Packaging
Field Name
Value
Description
Direction
DLE
10H
Delimiter
ENQ
05H
Enquiry
VS-900 to PC or
PC to VS-900
DLE
10H
Delimiter
ACK
06H
Acknowledge
VS-900 to PC or
PC to VS-900
DLE
10H
Delimiter
STX
02H
Start of Text
Message*
Varies
Remote Dial, Data Log
Request or Data Log
Request or Data Log
DLE
10H
Delimiter
ETX
03H
End of Text
BCC**
Varies
Block Check Character
VS-900 to PC or
PC to VS-900
DLE
10H
Delimiter
ACK
06H
Acknowledge
VS-900 to PC or
PC to VS-900
DLE
10H
Delimiter
EOT
04H
End of Transmission
VS-900 to PC or
PC to VS-900
* See the Remote Dial, Log Data Request or Log Data sections for more information.
** To calculate BCC, take the XOR of the combined Message, DLE, and ETX. (Refer to the shaded area
below). MS Windows Calculator (Scientific mode) is a useful tool for this function.
below). MS Windows Calculator (Scientific mode) is a useful tool for this function.
DLE
STX
MESSAGE
DLE
ETX
BCC